background image

13

13

tighten or replace connections as appropriate.

 

Warning: 

Do not use any naked flame to check for leaks.

2.  The operation of the appliance MUST be tested before leaving.
3.  Adjust the test point pressure or supply pressure to the value which is appropriate for 

the gas type.

4. 

Turn on the appliance gas controls and light each burner. Check for a well defined 

blue flame without any yellow tipping. If any abnormality is evident then check that the 

burner flame spreader and burner cap/s are both located properly.

5.  Check the minimum burner setting by quickly rotating the gas control knob from the 

maximum to the minimum position, the flame must not go out. If adjustment is required 

carry out the “MINIMUM BURNER SETTING ADJUSTMENT” procedure described 

below.

6.  If satisfactory performance cannot be obtained, the installer shall check the installation 

and notify the local gas supply authority for a gas supply problem, or if it is an appliance 

problem, our Customer Service Centre should be called to obtain the nearest authorized 

Elba Appl. AUS Service Agent.

7.  Where the appliance data plate cannot be easily read with the appliance in the 

installed position the duplicate data plate must be attached to adjacent surface and 

the duplicate Natural gas / ULPG conversion label should also be included where a 

Natural gas / ULPG conversion has been completed.

INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY

 

If this appliance has to be installed with a hose assembly, the installer shall refer to the 

network operator or gas supplier for confirmation of the gas type, if in doubt.

 

When used with a flexible hose, the connector on the wall should be between 800 mm 

to 850 mm above the floor and in the region outside the width of the appliance to a 

distance of 250 mm.

 

The supply connection point shall be accessible with the appliance installed.

 

Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certified.

 

The thread connection shall be Rp 1/2” (ISO 7-1) male.

 

IMPORTANT WARNING:

 After connection the installer must check that the hose is 

not kinked, subjected to abrasion or permanently deformed. The installer must check 

also that the hose is not near (or in contact) with any hot surfaces e.g. base of metal 

hotplate, underbench oven etc.

 

The hose assembly shall be as short as practicable and comply with relevant 

AS/NZS5601.1 requirements.

 

IMPORTANT WARNING:

 The installer shall ensure the hose assembly is restrained 

from accidental contact with the flue outlet of an underbench oven.

Summary of Contents for DEGHBG60

Page 1: ...OOKING INSTALLATION and SERVICE INSTRUCTIONS USE and CARE INSTRUCTIONS DEGHBG60 DEGHBG70 DEGHBG90 BUILT IN GAS ON GLASS COOKING HOBS distributed by ELBA Appliances Australia a Division of Fisher Payke...

Page 2: ...ed for that is for cooking foodstuffs Any other form of usage is to be considered as inappropriate and therefore dangerous The manufacturer declines all responsibility in the event of damage caused by...

Page 3: ...parts are within the limits allowed by the norms The complete safety of the appliance also depends on the correct use we therefore recommend to always pay a extreme attention while using the product e...

Page 4: ...y with unused appliances The various components of the appliance are recyclable Dispose of them in accordance with the regulations in force in your country If the appliance is to be scrapped remove th...

Page 5: ...pliance from the electrical power supply to avoid the possibility of electric shock and call Customer Service WARNING When correctly installed your product meets all safety requirements laid down for...

Page 6: ...rn correctly according to the current local regulations WARNING When correctly installed your product meets all safety requirements laid down for this type of product category However special care sho...

Page 7: ...rly qualified person in order to avoid a hazard N B The connection of the appliance to earth is mandatory If the installation requires alterations to the domestic electrical system call a qualified el...

Page 8: ...odel DEGHBG60 600 510 54 560 480 60 200 Model DEGHBG70 750 510 54 560 480 60 200 Model DEGHBG90 900 510 54 840 480 60 200 650 mm 500 mm 450 mm E F D G B A C Cooktop installed G 40 mm Space for connect...

Page 9: ...uired If the cooktop is installed above an oven the two appliances shall be connected to the gas and or electrical supply with independent connections Overhead clearances In no case shall the clearanc...

Page 10: ...g 3c Model DEGHBG70 spread the longer seal G1 around the left rear and right sides fig 3d Fasten the brackets F and R to the appropriate socket holes without tightening the screws S for the moment Mak...

Page 11: ...11 11 30 mm min 40 mm max 40 mm min S A R G G1 30 mm min 40 mm max S A F G G2 40 mm min Rear Fixing Brackets Front Fixing Brackets Figure 3f Figure 3g...

Page 12: ...els connect the gas supply directly to the appliance test point adaptor supplied with the conversion kit and ensure that the supply pressure is regulated to 2 75 kPa Do NOT force the elbow rotation pr...

Page 13: ...nstalled position the duplicate data plate must be attached to adjacent surface and the duplicate Natural gas ULPG conversion label should also be included where a Natural gas ULPG conversion has been...

Page 14: ...conversion procedure must be carried out only by an authorised person This appliance is suitable for use with Natural gas or Universal LPG check the gas type sticker attached to the appliance The nom...

Page 15: ...gulator and test point adaptor are supplied with the appliance packed with conversion kit The burners are designed so that regulation of primary air is not required J Auxiliary semi rapid and rapid bu...

Page 16: ...bed below Using a screwdriver turn screw A until the flame setting is correct fig 6 Dual burner model DEGHBG90 only For the dual burner set the minimum as indicated above for both the gas valves one f...

Page 17: ...or products on this appliance at any time Do NOT use or store flammable materials near this appliance Do NOT spray aerosols in the vicinity of this appliance while it is in use Before using for the fi...

Page 18: ...l burner check both the control knobs are in the closed position CONTROL KNOBS 8 Burner control knob 1 Auxiliary 9 Burner control knob 2 Semi rapid 10 Burner control knob 3 Semi rapid 11 Burner contro...

Page 19: ...maximum from Low Minimum To switch off turn the knob clockwise until you hear the safety click Note that if you are using a burner at the minimum setting you turn the knob clockwise past the maximum...

Page 20: ...cedure N B If your local gas supply makes it difficult to light the burner with the knob set to maximum set the knob to minimum and repeat the operation DUAL BURNER MODELS DEGHBG90 ONLY The Dual Burne...

Page 21: ...21 21 1 2 1 2 1 2 Figure 9 DUAL BURNER OPERATION CONTROL KNOBS MODEL DEGHBG90 ONLY IMPORTANT After using the dual burner check both the control knobs are in the closed position...

Page 22: ...an only one third full of oil DO NOT cover the pan with a lid and DO NOT leave the pan unattended In the unfortunate event of a fire leave the pan where it is and turn off all controls Place a damp cl...

Page 23: ...odels Warning The flat bottomed pans are to be placed directly onto the pan support To use the WOK you must place the wok stand in the CORRECT position as shown IMPORTANT The special grille for wok pa...

Page 24: ...the burner with a wok stand as this will concentrate and deflect heat onto the hotplate Do not use large pots or heavy weights which can bend the pan support or deflect flame onto the hotplate Locate...

Page 25: ...designed or intended to be touched and may contain sharp or rough edges that may cause injury GLASS SURFACE Remove spillages and other types of incrustations by using only specific products which do...

Page 26: ...the gas taps call the Service Department Figure 15 IMPORTANT WARNING NEVER unscrew the burner plate fixing screws fig 15 The burner plates can be removed ONLY by an authorised service agent Damage to...

Page 27: ...for the models DEGHBG70 DEGHGB90 only It is very important to check that the burner flame spreader F and the cap C have been correctly positioned see figs 16a and 16b Failure to do so can cause seriou...

Page 28: ...28 28 S T T S TRIPLE RING COMPACT BURNER Model DEGHBG60 TRIPLE RING BURNER Model DEGHBG70 A B T T S S DUAL BURNER Model DEGHBG90 Figure 16f Figure 16g Figure 16e Figure 16d Figure 16c F1 F2 F3...

Page 29: ...ed Failure to do so can cause serious problems The pan supports shall be level and must not rotate AUXILIARY SEMI RAPID AND RAPID BURNER Rapid for models DEGHBG70 DEGHBG90 only TRIPLE RING COMPACT mod...

Page 30: ...ners do not remain alight at the minimum marked setting The burner flame is yellow or emits an unusual odour Note that a bi annual inspection of the appliance by an authorized service agent or your lo...

Page 31: ...31 31...

Page 32: ...strations in this booklet are given as simply indicative The manufacturer reserves the right considering the characteristics of the models described here at any time and without notice to make eventua...

Reviews: