DeLonghi DEFSGG 24 SS Installation Instructions Manual Download Page 9

9

gas connection

Gas supply line

Shutoff valve

“open” position

To range

Explosion Hazard

Use a new CSA or UL approved
gas supply line.

Install a shut-off valve.

Securely tighten all gas connec-
tions.

If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.

Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.

Failure to do so can result in
death, explosion, or fire.

Fig. 2.1

All gas connections must be made according to national and local codes. This gas
supply (service) line must be the same size or greater than the inlet line of the
appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane
gas.

The range is equipped for the use with NATURAL gas. It is design-certified by CSA
International for NATURAL and L.P. gases with appropriate conversion.

The model/serial rating plate, located inside the drawer, has information on the type
of gas that can be used. If this information does not agree with the type of gas
available, check with the local gas supplier. See page from 13 to 16 for L.P. gas
conversion instructions.

1. Manual Shut-off Valve 

(fig: 2.1)

:

The supply line shall be equipped with an approved shutoff valve. This valve should
be located in the same room as the range and should be in a location that allows
ease of opening and closing (in a position where it can be reached quickly in the
event of an emergency).

Do not block access to the shutoff valve. The valve is for turning on or shutting off
gas to the appliance.

2. Pressure Regulator:

a)  All heavy duty, commercial type cooking equipment must have a pressure regulator

on the incoming service line for safe and efficient operation, since service pressure
may fluctuate with local demand. 

Before installing the regulator mount the 1/2” NPT (conical) male connector to the
regulator (see picture 2.2). Gasket supplied have to be placed between 1/2” NPT
(conical) connector/extension pipe male pipe fitting (see picture 2.3).

The regulator supplied with this range must be installed before any gas connections
are made.

Use supplied pressure regulator only.

Summary of Contents for DEFSGG 24 SS

Page 1: ...The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 for merly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Pa...

Page 2: ...ighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Page 3: ...f domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is...

Page 4: ...lified installer service agent or the gas supplier IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NE...

Page 5: ...lation should comply with national and local codes 11 Air Supply and Ventilation The installer must refers to local national codes 12 Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 11 0 W C P...

Page 6: ...urfaces above 36 914 mm high There must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of...

Page 7: ...13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 762 mm 457 mm 18 min PROXIMITY TO SIDE CABINETS Fig 1 3b ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as...

Page 8: ...o be attached as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide ran...

Page 9: ...type of gas that can be used If this information does not agree with the type of gas available check with the local gas supplier See page from 13 to 16 for L P gas conversion instructions 1 Manual Shu...

Page 10: ...ch Do not over tighten the connector Over tightening may crack regulator STEP 2 Assemble the 1 2 NPT connector pressure regulator group to the extension pipe interposing the gasket supplied The regula...

Page 11: ...cal male 1 2 NPT female 1 2 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented toward the connector Arrow Extension pipe fe...

Page 12: ...range can withstand a maximum input pressure of 1 2 PSI 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individual shut off valve...

Page 13: ...ers expressed in hundredths of a millimetre are marked on the body of each injector SETTING THE PRESSURE REGULATOR fig 2 6b The pressure regulator is accessible by removing the bottom drawer the press...

Page 14: ...0 109 34 180 adjustable Broil burner 8500 88 146 OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS Remove the gratings the burner covers and the knobs Using a wrench substitute the nozzle inj...

Page 15: ...indicated by the arrow in fig 2 11 and replace it by the proper one according to the kind of gas Then replace the burner repeating the above steps in reverse order b Broil Burner Remove the burner by...

Page 16: ...one only for the oven burner the broil is a fixed capacity by acting on the thermostat in the following way Turn on the burner by setting the thermostat knob on position Remove the knob and unscrew th...

Page 17: ...personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong ground type outlet ground...

Page 18: ...LF EC A M N L ELECTRIC DIAGRAM KEY F1 Switch MS Security microswitch S1 Cooling fan safety lamp LF Oven lamp AS Air switch V Fan TL3 Thermal overload PA Ignition switches group A Ignition coil EC Elec...

Page 19: ...19...

Page 20: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...

Reviews: