14
SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:
– Light the burner
– Set the gas valve to
position
– Remove the knob
– With a thin screwdriver pass by the hole of microswitch and turn the screw
F
until
adjustment is correct (fig. 2.9).
For LP/PROPANE gas, tighten the adjustment screws completely.
Fig. 2.9
Oven burner
13000
1500
109
34
180
adjustable
Broil burner
8500
-
88
-
146
-
OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING
THE INJECTORS
✓
Remove the gratings, the burner covers and the knobs;
✓
Using a wrench substitute the nozzle injectors “J” (figs. 2.7 - 2.8) with those most
suitable for the kind of gas for which it is to be used.
The burner are conceived in such a way so as not to require the regulation of the
primary air.
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
BURNERS
BTU/hr
BTU/hr
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Auxiliary (AUX)
3500
1000
55
27
90
adjustable
Semirapid (SR)
6000
1500
72
32
118
adjustable
Triple ring (TC)
12000
5000
102
65
170
adjustable
Fig. 2.7
J
F
Fig. 2.8
J
Summary of Contents for DEFSGG 24 SS
Page 19: ...19...