TABLE FOR THE CHOICE OF THE INJECTORS
Natural gas
ULPG
Test Point Pressure [kPa]
1.0
2.75
BURNER
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Auxiliary (A)
0.85
3.60
0.53
3.60
Semi-rapid (SR)
1.12
6.30
0.70
6.30
Rapid (R)
1.45
10.30
0.91
10.80
Triple ring (TR)
1.60
12.70
0.95
11.90
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismantle it carefully and clean it with petro-
leum spirit. Specialist high temperature resistant grease should be used to lubricate the tap
before replacing.
The operations must be carried out by an authorised person/service agent.