13
4. Turn on the appliance gas controls and light each burner individually and in combina-
tion. Check for a well defined blue flame without any yellow tipping. If any abnormality
is evident then check that the burner cap is located properly and the injector nipple is
aligned correctly.
5. Check the minimum burner setting by quickly rotating the gas control knob from the
maximum to the minimum position, the flame must not go out. If adjustment is required
carry out the “MINIMUM BURNER SETTING ADJUSTMENT” procedure described.
6. If satisfacfory performance cannot be obtained, the installer shall check the installation
and notify the local gas supply authority for a gas supply problem, or if it is an ap-
pliance problem, our Customer Service Centre should be called to obtain the nearest
authorized Delonghi Service Agent.
CONVERSION PROCEDURE (TO CONVERT TO NATURAL GAS OR TO ULPG)
REPLACING THE INJECTORS
This appliance is suitable for use with Natural gas or ULPG (check the “gas type” sticker
attached to the appliance). A label stating the type of gas used after replacing the injectors
must be attached at the rear of the appliance, in proximity of the gas inlet connection. The
nominal gas consumption and injector size details are provided in table at page 15.
To replace the injectors proceed as follows:
■
Remove pan supports and burners from the cooktop.
■
Using a spanner, remove the injector “
J
” (figs. 9, 10) and replace it with one according
to the gas type (see following tables - page 15).
■
Affix to the rear of the appliance, in proximity of the gas inlet connections, the warning
label (supplied with the conversion kit) stating that the cooker has been converted for
use with ULPG / Natural gas.
J
J
Figure 9
Figure 10