![DeLonghi DECH84SC Instructions For The Use Download Page 25](http://html1.mh-extra.com/html/delonghi-0/dech84sc/dech84sc_instructions-for-the-use_2470466025.webp)
25
CONNECTION OF THE POWER SUPPLY CABLE
Important! This cooktop must be connected to the electricity supply only by an
authorised person.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
To connect the feeder cable to the hob it is necessary to carry out the following operations:
•
Unlock the 2 clips “
B
” and open the cover “
C
”.
•
Unscrew the screw “
D
” and open completely the cable clamp “
E
” (figs. 4.6 - 4.7 - 4.8).
•
Position the “
U
” bolts “
F
” onto terminal board “
G
” (figs. 4.6 - 4.7 - 4.8) according to the
diagrams in fig. 4.5.
•
Connect the phase and earth wires to terminal board “
G
” according to the diagrams
in fig. 4.5.
•
Strain the feeder cable and block it with cable clamp “
E
” (by screwing screw “
D
”).
•
Close the cover “
C
” of the terminal board “
G
” and block it .
MODELS SUPPLIED WITHOUT POWER CORD
ALREADY FITTED TO THE APPLIANCE
MODELS SUPPLIED WITH POWER CORD
ALREADY FITTED TO THE APPLIANCE
FEEDER SPECIAL CABLE SECTION
WARNING - VERY IMPORTANT: THIS APPLIANCE IS SUPPLIED WITH POWER CORD
FOR SINGLE PHASE CONNECTION ONLY (220-240 V 50/60Hz)
For 60 cm and 80 cm models:
“Type H05V2V2-F (resistance to temperatures of 90°C)”
220-240 V ac 3 x 4 mm
2
(**)
(**) Connection with wall box connection.
For 90 cm models:
“Type H05BB-F (resistance to temperatures of 90°C)”
220-240 V ac 3 x 6 mm
2
(**)
(**) Connection with wall box connection.
FEEDER CABLE SECTION
“Type H05VV-F or H05V2V2-F or H05RR-F”
For 60 cm and 80 cm models:
220-240 V ac 3 x 2.5 mm
2
(**)
380-415 V 3N ac 5 x 1.5 mm
2
(**)
380-415 V 2N ac 4 x 2.5 mm
2
(**)
For 90 cm models:
220-240 V ac 3 x 4 mm
2
(**)
380-415 V 2N ac 4 x 2,5 mm
2
(**)
380-415 V 3N ac 5 x 2.5 mm
2
(**)
(**) Connection with wall box connection.
–
Diversity factor applied.
–
A diversity factor may be applied to the total loading of the appliance only by a suitably
qualified person.