12
Tr o u b l e s h o o t i n g
Problem
Cause
Solution
The appliance is operating
in dehumidification mode
(indicator light on), but the
humidity does not decrease
•filter clogged
•the temperature or humi-
dity of the room is too low
•the room is too large
•too many sources of humi-
dity in room (boiling pots
etc.)
•humidistat set too high
•clean the filter
•in certain conditions, it is
normal for the appliance
not to dehumidify (in these
cases the room being
dehumidified should also
be heated)
•decrease the humidity set
point
Check the following points before calling your local authorised Service Centre.
The appliance does not
work for around 3 minutes
when restarted
•the appliance’s safety devi-
ce has been activated
•wait for 3 minutes
The display shows “
Ft
”
•the tank is missing
•the tank is full
•the tank is in the wrong
position
•position the tank
•empty the tank
•position the tank correctly
The display shows “
Df
”
•the temperature in the room
is too low
•increase the ambient tem-
perature
The display shows “
fp
”
•one of the sensors on the
appliance is faulty
•call the Service Centre