background image

16

I m p o r t a n t   s a f e g u a rd s

This appliance is designed for home air conditioning and must not be used for other purposes.

It is dangerous to modify or alter the characteristics of the appliance in any way.

The appliance must be installed in conformity with legislation in force in the country concerned.

If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.  
Repairs carried out by unauthorised personnel may be dangerous.

If the power cable is damaged, it must be replaced by the manufacturer, an authorised service cen-
tre or a qualified electrician in order to eliminate all risk.

This appliance must be used exclusively by adults. 

Do not allow children or unfit persons to use the appliance without adequate supervision.

Do not allow children to play with the appliance.

he appliance must be connected to an efficient earth system. 
Have your electrical circuit checked by a qualified electrician.

Do not use extension cables.

Before cleaning or maintenance operations, always unplug the appliance from the mains socket.

Do not move the appliance by pulling the power cable.

Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.

Do not rest heavy or hot objects on top of the appliance.

Clean the anti-microbial filters at least once a week.

Avoid using heating appliances near the air conditioner.

Always transport the appliance upright or resting on one side.

Use the appliance as described in this instruction manual only.  As with all electrical equipment, whil-
st the instructions aim to cover as many eventualities as possible,  caution and common sense should
be applied when operating and installing this appliance.

At the end of its working life, take the appliance to a special collection centre.

The materials used for packaging can be recycled.  You are therefore recommended to dispose of
them in special differentiated waste collection containers.

The refrigerant gas R407c conforms to EC regulations on the environment.  Avoid perforating the refri-
gerant circuit of the appliance.

Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised
containers (e.g. aerosol cans).

DESCRIPTION

air outlet grille

control panel

handles

castors

filter

evaporator air intake grille

external unit fixing screws

cover for quick-fit coupling compart-
ment (some models only)

water drain hose

10

power cable compartment

11

external unit handle

12

two mounting brackets with screws

13

two spanners (some models only)

14

four wall plugs with screws (some
models only)

15

two belts with hooks

16

one frame with sheath

17

four protective caps for connectors
(some models only)

18

remote control unit

Summary of Contents for CF 1130

Page 1: ...f the appliance Clean the anti microbial filters at least once a week Avoid using heating appliances near the air conditioner Always transport the appliance upright or resting on one side Use the appl...

Page 2: ...he sheath by using the frame provided fig B B 6 c m 3 0 C Turn the appliance off and unplug from the mains Wait about 30 minutes before following the instructions below 1 Remove the screws and take of...

Page 3: ...TERNAL UNIT Install the internal unit in the room to be air conditioned It should usually be beneath a window or in any case near an outside wall The internal unit must be level The air intake and out...

Page 4: ...ded b Attach the belts to the mounts c Attach the other end of the belts securely The external unit can be installed on the same level as the internal unit or higher provi ded the difference in height...

Page 5: ...rogrammed operation increase temperature time button F Programmed operation decrease temperature time button G Display Displays the temperature values set and the programmed operating time H Timer in...

Page 6: ...en you need to cool and dehu midify the room To set operation of the appliance correctly press the E or F buttons until the desired temperature is displayed Then select the fan speed by pressing the F...

Page 7: ...A then select the requi red operating mode and other settings temperature fan speed etc Press the ON OFF button A again to place the appliance in standby mode Press the timer button D The timer light...

Page 8: ...ver on the rear of the remote control Replace the old batteries with two new LR03 AAA 1 5V batteries inserting them correctly see the instructions inside the battery compartment Replace the cover If t...

Page 9: ...blinds to make the appliance much more economical to run Never rest objects of any kind on the air conditioner Never obstruct the air intake or outlet gril les Make sure there are no heat sources in...

Page 10: ...tion The filter is housed in the intake grille To clean the filters extract as shown in figure Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water...

Page 11: ...ed the air conditioner is not powerful enough for the conditions or size of the room close the window eliminate the heat source clean or replace the filter clean or replace the filter Particular odour...

Page 12: ...tage see rating plate Max absorbed power during air conditioning Refrigerant Cooling capacity Internal unit dimensions width 480 mm height 840 mm depth 300 mm weight 44 kg External unit dimensions wid...