GB
23
All operations on the appliance must be carried out
E\© D© TXDOL½HG© SURIHVVLRQDO© ZKR© EHIRUH© SHUIRUP
-
ing maintenance must make sure the appliance is
turned off, cold and disconnected from the house-
hold mains.
The appliance contains a precise quantity of oil.
All repairs requiring the appliance to be opened
PXVW© EH© SHUIRUPHG© E\© D© TXDOL½HG© SURIHVVLRQDO© ,Q©
the event of oil leaks, contact your local dealer or a
TXDOL½HG©SURIHVVLRQDO
7. TROUBLESHOOTING
The appliance does not heat
up.
r
Check if the radiator is correctly connected to the mains power grid and powered.
r
Check the position of the mains switch of the installation.
r
Increase the temperature set point on the appliance regulator.
r
The safety device has tripped. Eliminate the cause of overheating (for example,
obstructions or covering).
r
Disconnect the appliance from the household mains for a few minutes to reset the elec-
tronic system.
r
,I©LW©VWLOO©GRHV©QRW©KHDW©XS©FRQWDFW©\RXU©ORFDO©GHDOHU©RU©D©TXDOL½HG©SURIHVVLRQDO
The appliance heats
continuously.
r
Reduce the temperature set point on the appliance regulator.
r
Make sure the “Overdrive (2h)” function has not been activated accidentally.
r
,I©LW©FRQWLQXHV©WR©KHDW©FRQWDFW©\RXU©ORFDO©GHDOHU©RU©D©TXDOL½HG©SURIHVVLRQDO
The room stays cold.
r
Make sure the power of the appliance is adequate for the room to be heated.
r
,I©WKH©DSSOLDQFH©LV©EHLQJ©XVHG©IRU©WKH©½UVW©WLPH©WKH©URRP©WDNHV©DW©OHDVW©D©FRXSOH©RI©KRXUV©WR©
heat to the required temperature (setting the radiator to maximum does not raise the tem-
perature more quickly).
Leaks of the liquid in the
appliance.
r
Turn the appliance off and contact your local dealer.
r
Dry the leaks using gloves to protect from the chemical products. Keep children and
pets away from the liquid.
The appliance does not
respond correctly to orders
received from the Pilot Wire
control unit.
r
Disconnect the appliance from the mains power supply (switch off the mains switch by
moving it in the “O” position). Make sure the connection is correct (Fig.7) and the control
unit is functioning correctly.
r
&RQWDFW©D©TXDOL½HG©SURIHVVLRQDO
The appliance keeps on
heating despite the window
is open.
r
It may be necessary to wait a few minutes before the function starts operating.
r
7KH©GLIIHUHQFH©EHWZHHQ©WKH©RXWVLGH©DQG©LQVLGH©WHPSHUDWXUH©PD\©QRW©EH©VXI½FLHQW©WR©DFWL
-
vate the function.
r
Check that the positioning of the appliance comply with the requirements referred to in
ch. 4.5.1 of this booklet.
r
Check that the area around the appliance Command is free of any obstacles.
r
,I©WKH©SUREOHP©SHUVLVWV©FRQWDFW©\RXU©GHDOHU©RU©TXDOL½HG©SHUVRQQHO
The appliance does not resume
heating after the window is
closed.
r
It may be necessary to wait a few minutes before before the sensor detects the window
closing.
r
Check that the area around the appliance Command is free of any obstacles.
r
Should the response time of the function be too long, you can at any time stop the radia-
tor manually.
r
,I©WKH©SUREOHP©SHUVLVWV©FRQWDFW©\RXU©GHDOHU©RU©TXDOL½HG©SHUVRQQHO
The right LED becomes
alternating yellow and red.
r
The temperature sensor is malfunctioning. Turn off the appliance and contact your dealer.