background image

METER READINGS

If the LED displays: 

The %MC is:

Blinking 6%

Below 5.5%

6%

Between 5.5 and 6.0

7%

Between 6.1 and 7.0

8%

Between 7.1 and 8.0

9%

Between 8.1 and 9.0

10%

Between 9.1 and 10.0

Blinking 10% and 12%

Between 10.1 and 11.0

12%

Between 11.1 and 12.0

Blinking 12% and 15%

Between 12.1 and 13.5

15%

Between 13.6 and 15.0

Blinking 15% and 17%

Between 15.1 and 16.0

17%

Between 16.1 and 17.0

Blinking 17% and 19%

Between 17.1 and 18.0

19%

Between 18.1 and 19.0

20%

Between 19.1 and 20.0

Blinking 20% and 25%

Between 20.1 and 22.5

25%

Between 22.6 and 25.0

Blinking 25% and 30%

Between 25.1 and 27.5

30%

Between 27.6 and 30.0

Blinking 30%

Above 30%

The J-Lite can be used to test more than just wood. It will also
give a relative reading on plywood, OSB, particleboard and MDF
or can be fitted with a 26-ES slide hammer for specific
applications. Call Delmhorst at 800-222-0638 or e-mail 
[email protected] for information on how to interpret the
readings for other materials.

4

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for J-Lite

Page 1: ...J Lite o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T TM www com information itm com 1 800 561 8187...

Page 2: ...tion 3 Taking a Reading 3 Understanding Your Readings 4 Meter Readings 5 Temperature Correction Table 5 Pin Talk 6 Care of Your Meter 6 Service For Your Meter 7 Warranty Species Correction Chart on Ba...

Page 3: ...ilt in calibration check hTemperature stable circuit hErgonomic case design hEasy one hand operation hIncludes 1 9 Volt Battery hIncludes sturdy carrying case hThree year warranty hOver fifty years of...

Page 4: ...rmation under the Pin Talk section hRemove the protective cover to expose the pins Check that the contact pins are firmly hand tightened hAlign the contact pins parallel to the grain pushing them thei...

Page 5: ...Between 17 1 and 18 0 19 Between 18 1 and 19 0 20 Between 19 1 and 20 0 Blinking 20 and 25 Between 20 1 and 22 5 25 Between 22 6 and 25 0 Blinking 25 and 30 Between 25 1 and 27 5 30 Between 27 6 and...

Page 6: ...EMP METER READINGS C F 6 7 10 15 20 25 30 35 40 50 60 20 0 9 11 15 22 31 38 45 53 10 20 8 10 14 20 28 34 40 47 55 5 40 7 8 12 18 24 30 36 42 48 15 60 6 7 11 16 21 27 32 38 43 54 30 80 6 7 9 14 19 23 2...

Page 7: ...oblem hThere is no need to call us for a return authorization number if you are within the U S Customers outside the U S must contact us for more specific instructions prior to returning a meter hIncl...

Page 8: ...7 19 21 23 25 26 CEDAR INCENSE 7 8 9 5 10 5 12 5 15 17 19 21 23 25 CHERRY 8 9 10 11 13 5 15 5 18 20 22 24 26 COTTONWOOD 6 7 5 8 5 9 5 12 14 15 17 19 5 21 23 CYPRESS 7 8 9 10 12 14 16 18 19 5 21 5 23 5...

Page 9: ...10 12 14 16 18 20 22 5 25 MERANTI DARK RED 8 5 9 5 10 5 11 5 12 5 16 18 20 5 22 5 24 5 26 5 OAK RED 7 8 9 10 12 14 16 18 20 22 24 OAK WHITE 7 8 8 5 9 5 11 5 13 5 15 17 18 5 20 22 PECAN 6 5 8 9 5 11 1...

Page 10: ...K 7 8 8 5 9 11 12 14 15 17 18 5 20 VIROLA 6 5 7 8 9 11 12 5 14 16 18 18 5 20 5 WALNUT BLACK 7 5 8 5 9 5 10 5 12 5 14 5 16 18 20 22 23 5 Meter readings taken with 26 E 2 pin electrode Do not apply 2 pi...

Reviews: