Delmhorst F-2000R Operation Manual Download Page 2

 

 

Model F-2000R  

Owner’s Manual 

 

 

TABLE OF CONTENTS 
 

3    

F-2000R Features 

3    

Before You Begin 

3    

Button Functions 

4    

Check Calibration 

4    

Change The Set Point  

4    

To Check The Accumulated Readings 

5    

To Reset The Meter 

5    

Recommended electrodes 

5    

Taking A Reading 

6    

Testing Reed stems 

6    

Testing in Roofing sheets 

6   

Factors Affecting Your Reading 

6   

Range Of Moisture Content 

7    

Reed Temperature 

7   

Curing 

7   

Density 

7  

Use Of Preservatives 

8    

In general 

8   

Care Of Your Meter 

9    

Service For Your Meter 

10 

Warranty 

11 

   Declaration of Conformity 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

This product is covered by EU directive 2002/96/EC (WEEE). For disposal 
please contact your supplier or local authorities for instructions as to best do so. 

 
 
 
 
 
 
 
 

Summary of Contents for F-2000R

Page 1: ...F 2000R REED MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Page 2: ...ng A Reading 6 Testing Reed stems 6 Testing in Roofing sheets 6 Factors Affecting Your Reading 6 Range Of Moisture Content 7 Reed Temperature 7 Curing 7 Density 7 Use Of Preservatives 8 In general 8 C...

Page 3: ...ibration Displays the average of up to 100 accumulated readings displays the highest stored reading erases the readings Set Point Decrease 3 Acts as an arrow button when pressed after the set point bu...

Page 4: ...e the button to stop at your desired set point If the meter reads a MC higher than that of the set point a buzzer will sound TO CHECK THE ACCUMULATED READINGS This feature allows you to view the total...

Page 5: ...1235 to the external connector on the top of the meter Insert the electrode into the reed bundle Press the read button 1 The meter displays the MC for two seconds NOTES The reed electrode is electrica...

Page 6: ...the electrical meter readings the indicated moisture content should not be used as an absolute quantitative measurement Meter readings are very useful guidelines for safe use of reed Meter readings b...

Page 7: ...en on different parts of the bundle The higher the moisture range the wider are the variations The more curing has been allowed to take place the greater uniformity in moisture distribution can be exp...

Page 8: ...ations among readings are greater If there is a possibility of high moisture areas samples from these locations should be taken Areas of high moisture content will spoil resulting in loss It is extrem...

Page 9: ...prepaid We are not responsible for damage in transit We do not accept COD shipments or cover any incoming freight or duty charges on returned merchandise Turnaround time on repairs is approximately t...

Page 10: ...MHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to t...

Page 11: ...Directive Standard s to which Conformity is declared EN 50082 1 1992 EMC Generic immunity standard EN 50081 1 1992 EMC Generic emission standard EN 55011 1991 Limits and methods of measurement of radi...