background image

3

USER TIPS

Portable Air conditioner is ideal for spot cooling. The compressor, condenser, and evaporator are built in a 

compack unit. The air is dehumidified and cooled while a flexible hose release heat outside.

Permanent installation is not necessary, This protable air conditioner is easy to move from room to room and 

offers a wide range of air conditioning solution.

To ensure optimal efficiency of the product, keep all doors and wondows closed when it is used as a air 

conditioner or dehmidifier. 

Leave window open to improve air circulation when using in fan mode.

Air conditioning / dehumidifying

operation

Fan

operation

IMPORTANT

:

Before installation, place the unit in a upright position for 1 hour to allow the refrigerant to settle. Air outlet 

will open automatically when the unit is turned on, and closes when turned off.

Follow installation instructions to set up the unit.

Summary of Contents for 048-GM-48382

Page 1: ...stallation please call DELLA customer service at 1 800 863 4143 Have this manual open and ready for reference CUSTOMER SERVICE 1 800 863 4143 9 00AM 6 00PM PST Monday Friday Model 048 GM 48382 USER S MANUAL 10K BTU PORTABLE AIR CONDITIONER CAUTION WARNING Do not use this device before reading these instructions manufacturer dellausa com www dellausa com ...

Page 2: ...mponents or connectors 14 DO NOT touch the power plug or handling the unit with wet hand to avoid electric shock 15 DO NOT unplug the unit by pulling the power cord 16 DO NOT operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been dropped or damaged in any manner 17 DO NOT use accessory attachments not recommended or sold by the manufacturer to prevent fir...

Page 3: ...e of air conditioning solution To ensure optimal efficiency of the product keep all doors and wondows closed when it is used as a air conditioner or dehmidifier Leave window open to improve air circulation when using in fan mode Air conditioning dehumidifying operation Fan operation IMPORTANT Before installation place the unit in a upright position for 1 hour to allow the refrigerant to settle Air...

Page 4: ...AGRAM Air Outlet Air Filter Air Filter Bottom Water Drain Upper Water Drain Power Cord Remote Control Exhaust Hose Window Slider Kit Drain Hose Exhaust Connector Window Adapter Exhaust Control Panel Handle ...

Page 5: ...d the exhaust hose and attach the connector to one end 2 Attach the connector to the back of the unit The air conditioner needs to be installed next to a window and connect the exhaust hose from the unit to the window INSTALLATION GUIDE 2 person assembly 15 mins ...

Page 6: ...6 3 Attach the window adapter to the other end of the exhaust hose 4 Attach the window adapter to the window slider kit INSTALLATION GUIDE CONTINUE ...

Page 7: ...7 INSTALLATION GUIDE CONTINUE 5 Adjust the length of the window slider kit according to your window ...

Page 8: ... Close the window sash on the window kit NOTE Cut the window kit if the window width is shorter than the minimum length of the window kit Cutting the window kit will reduce the maximum length if can extend INSTALLATION GUIDE CONTINUE Horizontal Vertical ATTENTION Make sure the exhaust hose is not folded as this could cause the unit to have lower efficiency or malfuction ...

Page 9: ...UTION WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded CAUTION WARNING DO NOT modify the plug provided with the product if it does not fit the outlet Have a proper outlet installed by a qualified electrician INSTALLATION GUIDE CO...

Page 10: ...en cooling fan dehumidifying and fan mode SPEED Toggle between fan speed A B C D E F A B D C E F Power Control Turn ON OFF Mode Control Control mode between Auto Cool Dry Fan C F Switch between C and F Auto Swing Enable the louver to swing automatically Speed Control Control fan speed Timer Control Enable Turn on turn off timer Sleep Control Enable sleep mode Adjusting temperature setting timer se...

Page 11: ... the fan indicator is lit Press the FAN SPEED button to choose the fan speed Turn ON Timer Press the timer button once when the unit is in stand by mode Plugged into power but have not power on Press and button to set your desire time Press the timer button again to cancel the setting Turn OFF Timer Press the timer button once when the unit is running in cool mode Press and button to set your desi...

Page 12: ...alkaline batteries carbon zinc batteries or rechargeable batteries All batteries should be replaced at the same time Remove batteries if the remote control is not used for a month or longer DO NOT put batteries next to or in a heat source such as fire electric heating device etc Rechargeable batteries should be charged under adult supervision only DO NOT hit batteries against hard object Using the...

Page 13: ...inage 1 Unplug the unit from all power source 2 Move the unit to a suitable drain location or place a empty container under the drain 3 Unplug the bottom drain plug to drain water from the unit 4 Replace the plug back on the unit once the draining is completed NOTE You may need to drain the unit more often if it is used in environments with higher humidity CARE AND MAINTENANCE WATER DRAINAGE ...

Page 14: ...it has been manually drained following the manual drainage instruction 2 Move the unit to a suitable drain location 3 Unplug the upper drain plug and insert the water drain hose 4 Place the other end to the drain location NOTE Make sure there is no leak from the hose connection ...

Page 15: ...ficiently 1 Unplug the unit from all power source 2 Remove the filter from the unit 3 Gentle immerse the filter in warm water 4 Mild detergent can be added to remove dirt particles and pollutants 5 Allow the filter to completely dry before placing back into the unit CAUTION WARNING DO NOT operate the unit without the air filter ...

Page 16: ...rom the remote control 5 Cover the unit with plastic sheet to protect from dust and debris 6 Store the unit in a dry cool place NOTE make sure you store your unit in location which is not subject to extreme temperature or direct sunlight 1 Make sure the power cord and the unit housing are in good condition and without any crack or damage 2 Make sure air filter and drain cap are in place 3 Place ne...

Page 17: ...emperature Change the set temperature Unit does not cool properly Room window or door is opened The unit work best in enclose area close the window or door Dirty Filter Clean the filter Air inlet vent or exhaust is obstructed Make sure nothing is obstructing the air flow Unusual noise level Unit is on uneven surface Place the unit on level and flat surface Remote Control does not work Too far away...

Page 18: ...18 ERROR CODE CHART Error Code Description Solution P1 Water Tank Full Drain the water ...

Page 19: ...r at the customer s expense If the reason of return is a result of an error by DELLA DELLA will provide a pre paid shipping label via email Boxes for return will not be provided by DELLA Customer will be responsible to use the original boxex or purchase new boxes Pictures may be required for some returns to ensure an item is not damage prior to the return WARNING Manufacturer and seller expressly ...

Page 20: ...20 ...