To validate the software image on the flash drive after the image is transferred to the system, but before you install the image, use the
verify {md5 | sha256} [ flash://]img-file [
hash-value
]
command in EXEC mode.
•
md5
: MD5 message-digest algorithm
•
sha256
: SHA256 Secure Hash Algorithm
•
flash:
(Optional) Specifies the flash drive. The default uses the flash drive. You can enter the image file name.
•
hash-value
: (Optional). Specify the relevant hash published on iSupport.
•
img-file
: Enter the name of the Dell Networking software image file to validate
Examples: Without Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin
MD5 hash for FTOS-SE-9.5.0.0.bin: 275ceb73a4f3118e1d6bcf7d75753459
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
SHA256 hash for FTOS-SE-9.5.0.0.bin:
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
Examples: Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin 275ceb73a4f3118e1d6bcf7d75753459
MD5 hash VERIFIED for FTOS-SE-9.5.0.0.bin
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.bin
Using HTTP for File Transfers
Stating with Release 9.3(0.1), you can use HTTP to copy files or configuration details to a remote server. To transfer files to an external
server, use the
copy source-file-url http://host[:port]/file-path
command.
Enter the following
source-file-url
keywords and information:
•
To copy a file from the internal FLASH, enter flash:// followed by the filename.
•
To copy the running configuration, enter the keyword running-config.
•
To copy the startup configuration, enter the keyword startup-config.
•
To copy a file on the USB device, enter usbflash:// followed by the filename.
In the Dell Networking OS release 9.8(0.0), HTTP services support the VRF-aware functionality. If you want the HTTP server to use a VRF
table that is attached to an interface, configure that HTTP server to use a specific routing table. You can use the
ip http vrf
command
to inform the HTTP server to use a specific routing table. After you configure this setting, the VRF table is used to look up the destination
address.
NOTE:
To enable HTTP to be VRF-aware, as a prerequisite you must first define the
VRF.
You can specify either the management VRF or a nondefault VRF to configure the VRF awareness setting.
When you specify the management VRF, the copy operation that is used to transfer files to and from an HTTP server utilizes the VRF table
corresponding to the Management VRF to look up the destination. When you specify a nondefault VRF, the VRF table corresponding to
that nondefault VRF is used to look up the HTTP server.
60
Getting Started
Summary of Contents for S4048T-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Page 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Page 251: ...Dell Control Plane Policing CoPP 251 ...
Page 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Page 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Page 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Page 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Page 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Page 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Page 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Page 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...