Snapshot group
•
Snapshot virtual disk
•
Consistency group member virtual disk
•
Replicated Pair
NOTE: Changing the modification priority by using this option modifies the priority only for the overall repository
that you selected. The settings are applied to all individual repository virtual disks contained within the overall
repository.
To change the modification priority:
1.
In the AMW, select the Storage & Copy Services tab.
2.
Select the storage object for which to change the modification priority.
3.
From the menu bar, select Overall Repository
→
Change Modification Priority.
The Change Disk Pool Settings window is displayed.
4.
In the Select modification priority area, move the slider bar to select a priority level.
5.
Click OK.
Changing The Media Scan Setting Of An Overall Repository Virtual Disk
Use the Change Media Scan Settings option to set the media scan settings for an overall repository virtual disk on a
storage array.
You can change the media scan settings for an overall repository for the following storage objects:
•
Snapshot group
•
Snapshot virtual disk
•
Consistency group member virtual disk
•
Replicated pair
The following guidelines apply:
•
Changing the media scan settings by using this option modifies the settings only for the overall repository that
you selected.
•
The settings are applied to all individual repository virtual disks contained within the overall repository.
To change the media scan settings:
1.
In the AMW, select the Storage & Copy Services tab and select any virtual disk.
2.
Select the storage object for which to change the media scan settings.
3.
Select Overall Repository
→
Change Media Scan Settings.
The Change Media Scan Settings window is displayed.
4.
Select Enable media scan.
5.
Select either With consistency check or Without consistency check, and click OK.
A consistency check scans the blocks in a RAID Level 5 virtual disk, or a RAID Level 6 virtual disk and checks the
consistency information for each block. A consistency check compares data blocks on RAID Level 1 mirrored
physical disks. RAID Level 0 virtual disks have no data redundancy.
Changing The Pre-read Consistency Check Setting Of An Overall Repository Virtual Disk
Use the Pre-Read Consistency Check option to define a storage array's capability to pre-read an overall repository
virtual disk consistency information and determine whether the data of that overall repository virtual disk is consistent.
147
Summary of Contents for PowerVault MD Series
Page 1: ...Dell PowerVault MD Series Storage Arrays Administrator s Guide ...
Page 14: ...21 Getting Help 237 Contacting Dell 237 ...
Page 46: ...46 ...
Page 62: ...62 ...
Page 96: ...96 ...
Page 108: ...108 ...
Page 114: ...114 ...
Page 152: ...152 ...
Page 164: ...164 ...
Page 174: ...3 Select Copy Remove Copy Pairs The Remove Copy Pairs dialog is displayed 4 Click Yes 174 ...
Page 184: ...184 ...
Page 212: ...212 ...
Page 220: ...220 ...