Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions

1.

Carefully insert the replacement enclosure services module into the mod-
ule bay. Push the module all the way to the back of the bay until it is seated 
in the connector.

2. Using a Phillips-head screwdriver, tighten the captive screw at the top of 

the enclosure services module to secure the module to the chassis.

3. Repeat steps 1 and 2 to install the remaining enclosure services module.

Install the Cooling Fans

NOTICE: In a nonredundant system, install the cooling-fan blank in 

the same cooling-fan bay from which it was removed.

NOTE: In a redundant storage system, there are three cooling fans. In a nonre-
dundant storage system there are two cooling fans and one cooling-fan blank. 
Because a cooling fan and a cooling-fan blank are installed in the same manner, 
both components are referred to as a cooling fan in this procedure.

To install the cooling fans, perform the following steps:

1.

Carefully slide the cooling fan into the empty cooling-fan bay. Push the 
cooling fan all the way to the back of the bay until it is seated in the 
connector. 

2. Using a Phillips-head screwdriver, turn the two captive screws clockwise 

until the cooling fan is secured to the cooling-fan bay.

3. Repeat steps 1 and 2 to install the remaining cooling fans.

Install the Power Supplies

NOTICE: In a nonredundant system, install the power supply and the 

power-supply blank in the same power-supply bays from which they 

were removed.

NOTE: In a redundant storage system, there are two power supplies. In a non-
redundant storage system there is one power supply and one power-supply 
blank. Because a power supply and a power-supply blank are installed in the 
same manner, both components are referred to as a power supply in this 
procedure.

To install the power supplies, perform the following steps:

1.

Carefully slide the power supply into the empty power-supply bay. Push the 
power supply all the way to the back of the bay until it is seated in the 
connector. 

2. Using a Phillips-head screwdriver, turn the two captive screws clockwise 

until the new power supply is secured to the power-supply bay.

3. Repeat steps 1 and 2 to install the remaining power supply.

Summary of Contents for PowerVault 200S

Page 1: ...KING INSIDE THE STORAGE SYSTEM Before you start to work on the storage system perform the following steps in the sequence listed 1 Turn off the storage system 2 Disconnect the storage system from its power source s 3 Disconnect any communications cables 4 Wear a wrist grounding strap and clip it to an unpainted metal sur face such as a part of the chassis If a wrist grounding strap is not availabl...

Page 2: ...s expander modules 12 Install the cooling fans 13 Install the power supplies 14 Install the hard disk drives Each procedure is described in the following sections Remove the SCSI Hard Disk Drives CAUTION Note the location of the SCSI hard disk drives as you remove them from the drive bays During the installation procedure found later in this document you must return the SCSI hard disk drives to th...

Page 3: ...n the lock bar and gently pull it toward you about 1 2 inch away from the unlocked keylock b Slide the left end of the lock bar to the right to remove it from its hole see Figure 2 Figure 2 Keylock and Removable Lock Bar Black 3 Remove the hard disk drives NOTICE Handle the hard disk drives with care The carriers pro vide some protection but the hard disk drives can be damaged by rough handling Wh...

Page 4: ...the power supply bays During the installation procedure found later in this document you must return the power supply and the power supply blank to the same power supply bays from which they were removed NOTE A redundant storage system has two power supplies A nonredundant storage system has one power supply and one power supply blank Because a power supply and a power supply blank are removed in ...

Page 5: ...ove the remaining power supply Remove the Cooling Fans NOTICE In a nonredundant system note that the cooling fan blank is located in the right cooling fan bay During the installation proce dure found later in this document you must return the cooling fan blank to the right cooling fan bay NOTE A redundant storage system has three cooling fans A nonredundant storage system has two cooling fans and ...

Page 6: ...erminator blank to the same module bays from which they were removed NOTICE In a redundant system note the location of the enclosure services or enclosure services expander modules as you remove them from the module bays During the installation procedure found later in this document you must return these modules to the same module bays from which they were removed NOTE A redundant storage system h...

Page 7: ...dule bay see Figure 7 Figure 7 Enclosure Services Module Removal 3 Repeat steps 1 and 2 to remove the remaining enclosure services module Remove the Component Mounting Bracket To remove the component mounting bracket perform the following steps 1 Using a Phillips head screwdriver remove the two screws that secure the component mounting bracket to the chassis see Figure 8 2 Lift the component mount...

Page 8: ... wiggle motion pull the module from the backplane board see Figure 9 Figure 9 Dual Bus Split Backplane Module Location Remove the SCSI Backplane Board To remove the SCSI backplane board perform the following steps 1 Looking in the rear of the storage system locate the fifteen screws that secure the two halves of the chassis together There are nine across the top and six across bottom of the backpl...

Page 9: ...enclosure services module bays on the left and right side of the chassis see Figure 11 NOTE A magnetized 11 5 inch long 5 64 inch ball head driver is included with the SCSI backplane board in the service kit Figure 11 Screw Location in the Left Enclosure Services Module Bay 3 Separate the two chassis halves to remove the backplane board see Figure 12 Figure 12 Chassis Separation image shown withou...

Page 10: ...f of the chassis Do not tighten the screws at this time NOTE If the front half of the chassis is slightly bowed down making it dif ficult to align the screw holes try installing a hard disk drive temporarily into one of the center drive bays The hard disk drive should straighten the bow in the chassis making it easier to thread the screws Remove the hard disk drive when all the screws are inserted...

Page 11: ...the bottom of the housing goes into the slot on the center support of the component mounting bracket 3 Insert the two screws and using a Phillips head screwdriver tighten the screws to secure the component mounting bracket to the chassis Install the Enclosure Services Modules or Enclosure Services Expander Modules NOTICE In a nonredundant system install the enclosure services module or enclosure s...

Page 12: ... into the empty cooling fan bay Push the cooling fan all the way to the back of the bay until it is seated in the connector 2 Using a Phillips head screwdriver turn the two captive screws clockwise until the cooling fan is secured to the cooling fan bay 3 Repeat steps 1 and 2 to install the remaining cooling fans Install the Power Supplies NOTICE In a nonredundant system install the power supply a...

Page 13: ...arrier handle flips up Figure 13 Installing a SCSI Hard Disk Drive System Shown with a Swing out Lock Bar 2 Close the handle to draw the drive carrier into the bay and lock the drive in place 3 Repeat steps 1 and 2 to install the remaining hard disk drives 4 For a storage system with a silver swing out lock bar raise the lock bar to the lock position The lock bar slips down into a detent This hold...

Page 14: ...e the Dell PowerVault 200S 201S 210S and 211S Storage Systems Installation and Service Guide After replacing the SCSI backplane board complete the procedure by perform ing the following steps 1 Install the storage system in the rack from which it was removed If the storage system was used in a stand alone configuration install the storage system in the stand alone enclosure 2 Connect the communica...

Reviews: