Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions

Install the Replacement SCSI Backplane Board

To install the replacement SCSI backplane board, perform the following steps:

1.

Place the board between the chassis halves. Ensure that the board is right 
side up and the dual-bus split backplane module faces the back half while 
the eight hard-disk drive connectors face the front half.

2. Using the magnetized 11.5-inch–long, 5/64-inch ball-head Allen driver, 

thread two screws through the left enclosure services module bay, 
through the screw holes in the backplane board, and into the screw holes 
of the front half of the chassis. Turn the screws until they catch in the 
screw holes of the front half of the chassis. Do 

not

 tighten the screws at 

this time. Install the two screws in the right enclosure services module bay 
in the same manner.

NOTE: The magnetized 11.5-inch–long, 5/64-inch ball-head Allen driver 
(included in the service kit) makes it easier to install the screws in the 
enclosure services module bays. 

3. Thread the eleven remaining screws through the inside of the component 

area of the back chassis half, through the screw holes in the backplane 
board, and into the screw holes of the front half of the chassis. Turn the 
screws until they catch in the screw holes of the front half of the chassis. 
Do 

not

 tighten the screws at this time.

NOTE: If the front half of the chassis is slightly bowed down, making it dif-
ficult to align the screw holes, try installing a hard-disk drive temporarily 
into one of the center drive bays. The hard-disk drive should straighten the 
bow in the chassis, making it easier to thread the screws. Remove the 
hard-disk drive when all the screws are inserted.

4. Carefully insert the left enclosure services module or enclosure services 

expander module into the left module bay. Push the module all the way to 
the back of the bay and at the same time adjust the backplane board so 
that the board connector aligns with the module connector. Push the mod-
ule until it is seated in the board connector.

NOTE: Temporarily installing the enclosure services modules or enclosure 
services expander modules and seating their connectors to the connectors 
on the backplane board ensures that the backplane board will be aligned as 
the two chassis halves are screwed together.

5. Using a Phillips-head screwdriver, tighten the screw to secure the enclo-

sure services module or enclosure services expander module to the 
chassis.

6. Repeat steps 4 and 5 for the right (second) enclosure services module, 

enclosure services expander module, or terminator blank.

7.

Tighten the eleven screws on the inside of the component area to secure 
the chassis front, backplane board, and chassis back together.

8. Using a Phillips-head screwdriver, loosen the captive screws at the top of 

the enclosure services modules.

Summary of Contents for PowerVault 200S

Page 1: ...KING INSIDE THE STORAGE SYSTEM Before you start to work on the storage system perform the following steps in the sequence listed 1 Turn off the storage system 2 Disconnect the storage system from its power source s 3 Disconnect any communications cables 4 Wear a wrist grounding strap and clip it to an unpainted metal sur face such as a part of the chassis If a wrist grounding strap is not availabl...

Page 2: ...s expander modules 12 Install the cooling fans 13 Install the power supplies 14 Install the hard disk drives Each procedure is described in the following sections Remove the SCSI Hard Disk Drives CAUTION Note the location of the SCSI hard disk drives as you remove them from the drive bays During the installation procedure found later in this document you must return the SCSI hard disk drives to th...

Page 3: ...n the lock bar and gently pull it toward you about 1 2 inch away from the unlocked keylock b Slide the left end of the lock bar to the right to remove it from its hole see Figure 2 Figure 2 Keylock and Removable Lock Bar Black 3 Remove the hard disk drives NOTICE Handle the hard disk drives with care The carriers pro vide some protection but the hard disk drives can be damaged by rough handling Wh...

Page 4: ...the power supply bays During the installation procedure found later in this document you must return the power supply and the power supply blank to the same power supply bays from which they were removed NOTE A redundant storage system has two power supplies A nonredundant storage system has one power supply and one power supply blank Because a power supply and a power supply blank are removed in ...

Page 5: ...ove the remaining power supply Remove the Cooling Fans NOTICE In a nonredundant system note that the cooling fan blank is located in the right cooling fan bay During the installation proce dure found later in this document you must return the cooling fan blank to the right cooling fan bay NOTE A redundant storage system has three cooling fans A nonredundant storage system has two cooling fans and ...

Page 6: ...erminator blank to the same module bays from which they were removed NOTICE In a redundant system note the location of the enclosure services or enclosure services expander modules as you remove them from the module bays During the installation procedure found later in this document you must return these modules to the same module bays from which they were removed NOTE A redundant storage system h...

Page 7: ...dule bay see Figure 7 Figure 7 Enclosure Services Module Removal 3 Repeat steps 1 and 2 to remove the remaining enclosure services module Remove the Component Mounting Bracket To remove the component mounting bracket perform the following steps 1 Using a Phillips head screwdriver remove the two screws that secure the component mounting bracket to the chassis see Figure 8 2 Lift the component mount...

Page 8: ... wiggle motion pull the module from the backplane board see Figure 9 Figure 9 Dual Bus Split Backplane Module Location Remove the SCSI Backplane Board To remove the SCSI backplane board perform the following steps 1 Looking in the rear of the storage system locate the fifteen screws that secure the two halves of the chassis together There are nine across the top and six across bottom of the backpl...

Page 9: ...enclosure services module bays on the left and right side of the chassis see Figure 11 NOTE A magnetized 11 5 inch long 5 64 inch ball head driver is included with the SCSI backplane board in the service kit Figure 11 Screw Location in the Left Enclosure Services Module Bay 3 Separate the two chassis halves to remove the backplane board see Figure 12 Figure 12 Chassis Separation image shown withou...

Page 10: ...f of the chassis Do not tighten the screws at this time NOTE If the front half of the chassis is slightly bowed down making it dif ficult to align the screw holes try installing a hard disk drive temporarily into one of the center drive bays The hard disk drive should straighten the bow in the chassis making it easier to thread the screws Remove the hard disk drive when all the screws are inserted...

Page 11: ...the bottom of the housing goes into the slot on the center support of the component mounting bracket 3 Insert the two screws and using a Phillips head screwdriver tighten the screws to secure the component mounting bracket to the chassis Install the Enclosure Services Modules or Enclosure Services Expander Modules NOTICE In a nonredundant system install the enclosure services module or enclosure s...

Page 12: ... into the empty cooling fan bay Push the cooling fan all the way to the back of the bay until it is seated in the connector 2 Using a Phillips head screwdriver turn the two captive screws clockwise until the cooling fan is secured to the cooling fan bay 3 Repeat steps 1 and 2 to install the remaining cooling fans Install the Power Supplies NOTICE In a nonredundant system install the power supply a...

Page 13: ...arrier handle flips up Figure 13 Installing a SCSI Hard Disk Drive System Shown with a Swing out Lock Bar 2 Close the handle to draw the drive carrier into the bay and lock the drive in place 3 Repeat steps 1 and 2 to install the remaining hard disk drives 4 For a storage system with a silver swing out lock bar raise the lock bar to the lock position The lock bar slips down into a detent This hold...

Page 14: ...e the Dell PowerVault 200S 201S 210S and 211S Storage Systems Installation and Service Guide After replacing the SCSI backplane board complete the procedure by perform ing the following steps 1 Install the storage system in the rack from which it was removed If the storage system was used in a stand alone configuration install the storage system in the stand alone enclosure 2 Connect the communica...

Reviews: