Table 5. Embedded module LEDs (continued)
LED
Location
State
Description
Node power
Green
Node is on (main power).
Green blinking
Node is initializing a serial over LAN
session.
Off
Node is off.
Node fault
Amber
Fault has occurred.
Blue
Node in Degraded Mode.
Amber or blue
blinking
System is booting.
Blue and amber
alternating (green
for 3 seconds)
System not initialized. A management IP
address has not been assigned.
Blue and amber
alternating at one
second intervals
Node in Service Mode.
Off
No fault has occurred, normal operation.
4-port card port link
Green
Link up with high speed
Amber
Link up with degraded speed
Off
Link down
Ethernet port activity
Amber blinking
Port activity.
Off
No port activity.
Ethernet port link
Green
Link established.
Off
No link established.
SAS port/activity link
Blue
Not used
Off
Not used
2-port card port link
Embedded module power
Amber
Embedded module has faulted.
Off
No fault has occurred, normal operation.
Power down the node
Power down the node as described in
.
Remove the node
This procedure describes how to remove a node from the chassis. There are two nodes. The top node is considered to be
upside-down and mirrors the bottom node. The procedure for removing the top node and the bottom node is the same.
Prerequisites
If the I/O modules and network cables are not already labeled, label them clearly for reconnecting later.
50
Base enclosure service procedures