Troubleshooting A Wet System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2.
Open the system.
3.
Disassemble components from the system:
– Hard drives
– Hard-drive backplane
– USB memory key
– Cooling shroud
– Expansion cards
– Power supply(s)
– Cooling fans
– Processor(s) and heat sink(s)
– Memory modules
4.
Let the system dry thoroughly for at least 24 hours.
5.
Reinstall the components you removed in step 3.
6.
Close the system.
7.
Turn on the system and attached peripherals.
If the system does not start properly, see
Getting Help
.
8.
If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed.
9.
Run the appropriate diagnostic test.
If the tests fail, see
Getting Help
.
Troubleshooting A Damaged System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2.
Open the system.
3.
Ensure that the following components are properly installed:
– Cooling shroud
– Expansion cards
– Power supply(s)
– Cooling fans
– Processor(s) and heat sink(s)
– Memory modules
107