Error Code
Message Information
LCD Message
Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue persists,
see
Getting Help
.
PST0128
Message
No memory is detected.
LCD Message
No memory is detected. Inspect memory devices.
Details
System BIOS was unable to detect memory in the system.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
PST0129
Message
Memory is detected, but is not configurable.
LCD Message
Memory is detected, but is not configurable. Check memory devices.
Details
System BIOS detected memory, but was unable to configure the
memory for system operation.
Action
Compare system memory installation to supported system memory
configurations.
PSU0001
Message
Power supply <
number
> failed.
LCD Message
PSU <
number
> failed. Check PSU.
Action
Remove and reinstall the power supply. If the issue persists, see
Getting Help
.
PSU0002
Message
A predictive failure detected on power supply <
number
>.
LCD Message
Predictive failure on PSU <
number
>. Check PSU.
Details
System performance and power redundancy may be degraded or
lost.
Action
Remove and reinstall the power supply at the next service window. If
the issue persists, see
Getting Help
.
PSU0003
Message
The power input for power supply <
number
> is lost.
LCD Message
Power input for PSU <
number
> is lost. Check PSU cables.
Details
The power supply is installed correctly but an input source is not
connected or is not functional.
Action
Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
134