3-2
Dell PowerEdge 4200 Systems Service Manual
1-3-1-1
DRAM refresh failure
Remove and reseat the
DIMMs (see Chapter 4) and
then reboot the system. If
the problem persists, replace
the system board.
1-3-1-3
Keyboard controller
error
Check the keyboard cable
and connector for proper
connection. If the problem
persists, run the Keyboard
Test Group in the system
diagnostics to determine
whether the keyboard or
keyboard controller is
faulty.
1-3-3-1
No DIMM memory
installed
Remove and reseat the
DIMMs. If the problem per-
sists, replace the system
board.
1-3-4-1
1-3-4-3
1-4-1-1
DRAM failure
Remove and reseat the
DIMMs. If the problem per-
sists, run the RAM Test
Group in the system diag-
nostics. If the problem still
persists, replace the system
board.
1-4-2-1
CMOS failure
Run the System Set Test
Group in the system diag-
nostics to isolate the prob-
lem.
1-4-3-1
Memory controller fail-
ure or DIMM failure
Check the DIMMs to ensure
that they are properly
seated. If the problem per-
sists, run the RAM Test
Group in the system diag-
nostics.
2-2-3-1
Unexpected interrupt
Ensure that all expansion
cards are properly seated,
and then reboot the system.
3-2-2-1
4-2-4-4
Gate A20 failure
Replace the system board.
4-2-4-3
Keyboard controller
error
Replace the system board.
Table 3-1. Beep Codes
(continued)
Code
Cause
Action
Summary of Contents for PowerEdge 4200 Series
Page 1: ... HOO 3RZHU GJH 6 VWHPV 6 59 0 18 ...
Page 2: ......
Page 3: ... HOO 3RZHU GJH 6 VWHPV 6 59 0 18 ...
Page 52: ...3 8 Dell PowerEdge 4200 Systems Service Manual ...
Page 90: ...A 12 Dell PowerEdge 4200 Systems Service Manual ...
Page 95: ......
Page 96: ... www dell com Printed in the U S A P N 55472 ...