Information Update
15
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2950 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.
Table 1-2.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user
in the System Setup
program.
The
SYSTEM NAME
displays under the
following conditions:
• The system
is powered on.
• The power is off
and active errors
are displayed.
This message is for
information only.
You can change
the system ID and
name in the System
Setup program.
See “Using the System
Setup Program” in the
Hardware Owner’s
Manual
.
E1000
FAILSAFE,
Call Support
Check the system event
log for critical failure
events.
See “Getting Help” in
the
Hardware Owner’s
Manual
.
E1118
CPU Temp
Interface
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.
Turn off power to the
system and restart the
system. If the problem
persists, see “Getting
Help” in the
Hardware
Owner’s Manual
.
Summary of Contents for PowerEdge 2950
Page 1: ...Dell PowerEdge 2950 Systems Information Update ...
Page 25: ...Dell PowerEdge 2950 系统 信息更新 ...
Page 28: ...28 目录 操作系统信息 45 枚举 NIC 45 RHEL 错误的处理器信息 45 Microsoft Windows 2000 的系统支持 46 系统诊断程序更新 46 ...
Page 47: ...Systèmes Dell PowerEdge 2950 Mise à jour des informations ...
Page 76: ...76 Mise à jour des informations ...
Page 77: ...Dell PowerEdge 2950 Systeme Informationsaktualisierung ...
Page 105: ...Dell PowerEdge 2950 システム アップデート情報 ...
Page 133: ...Dell PowerEdge 2950 시스템 정보 갱신본 ...
Page 158: ...158 정보 갱신본 ...
Page 159: ...Sistemas Dell PowerEdge 2950 Actualización de información ...
Page 186: ...186 Actualización de información ...