18
Cisco Nexus B22 Fabric Extender for Dell Getting Started Guide
Configuring the Cisco Nexus B22 Fabric Extender for Dell
This example shows how to display the environment status for a specific Fabric Extender unit:
N5596-2-Dell#
show environment fex 132
Temperature Fex 132:
-----------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-----------------------------------------------------------------
1 Die-1 110 105 52 ok
N5596-2-Dell#
This example shows how to display the SPROM for a specific Fabric Extender unit:
N5596-2-Dell# show sprom fex 160 all
DISPLAY FEX 160 SUP sprom contents
Common block:
Block Signature : 0xabab
Block Version : 3
Block Length : 160
Block Checksum : 0x1834
EEPROM Size : 65535
Block Count : 3
FRU Major Type : 0x6002
FRU Minor Type : 0x0
OEM String : Cisco Systems, Inc.
Product Number : N2K-B22DELL-P
Serial Number : FOC162511NQ
Part Number : 73-14668-02
Part Revision : 04
Mfg Deviation : 0
H/W Version : 0.203
Mfg Bits : 0
Engineer Use : 0
snmpOID : 9.12.3.1.9.78.14.0
Power Consump : 625
RMA Code : 0-0-0-0
CLEI Code : Cxxxx
VID : V00
Supervisor Module specific block:
Block Signature : 0x6002
Block Version : 2
Block Length : 103
Block Checksum : 0x27e9
Feature Bits : 0x0
HW Changes Bits : 0x0
Card Index : 11074
MAC Addresses : 00-00-00-00-00-00
Number of MACs : 0
Number of EPLD : 0
Port Type-Num : 1-8
Sensor #1 : -128,-128
Sensor #2 : -128,-128
Sensor #3 : -128,-128
Sensor #4 : -128,-128
Sensor #5 : -128,-128
Sensor #6 : -128,-128
Sensor #7 : -128,-128
Sensor #8 : -128,-128
Max Connector Power: 625
Cooling Requirement: 8
Ambient Temperature: 40