2
Dell Networking 207 Series Access Points
| Installation Guide
* Blinking: 1s on/1s off
**Flashing: off a fraction of a second every 2s
Figure 2
Back Panel
Console Port
The serial console port is located at the back of the 207 Series
access points and is a 4-pin connector covered by a dust cover.
An optional serial adapter cable (AP-CBL-SER) is sold
separately to connect the access points to a serial terminal or a
laptop for direct local management.
Ethernet Port
The 207 Series access points are equipped with one
10/100/1000Base-T (RJ-45) auto-sensing, MDI/MDX
Ethernet port (ENET0) for wired network connectivity. This
port supports IEEE 802.3af Power over Ethernet (PoE), as a
standard defined Powered Device (PD) from a Power
Sourcing Equipment (PSE) such as a PoE midspan injector or
network infrastructure that supports PoE.
Kensington Lock Slot
The 207 Series access points are equipped with a Kensington
lock slot for additional security.
Reset Button
To reset the 207 Series access points to factory default
settings, press and hold down the reset button using a small,
narrow object such as a paper clip while the access points are
powered on.
DC Power Socket
If PoE is not available, an optional AP-AC-12V30B power
adapter kit (sold separately) can be used to power the 207
Series access points.
Additionally, a locally-sourced AC-to-DC adapter (or any DC
source) can be used to power this device, as long as it
complies with all applicable local regulatory requirements and
the DC interface meets the following specifications:
12 Vdc (+/- 5%) and at least 12W
Center-positive 2.1/5.5 mm circular plug, 9.5 mm length
Before You Begin
Radio
Status
(Right)
Off
Device powered off, or both radios
disabled
Green- Solid
Both radios enabled in access mode
Green-
Blinking
One radio enabled in access mode
Amber- Solid
Both radios enabled in monitor mode
Amber-
Blinking
One radio enabled in monitor mode
Alternating
Green: one radio in access mode
Amber: one radio in monitor mode
LED
Color/
State
Meaning
Console Port
Ethernet Port
DC Power Socket
Reset Button
Kensington
Lock Slot
CAUTION: FCC Statement: Improper termination of
access points installed in the United States
configured to non-US model controllers will be in
violation of the FCC grant of equipment authorization.
Any such willful or intentional violation may result in a
requirement by the FCC for immediate termination of
operation and may be subject to forfeiture (47 CFR
1.80).
ATTENTION: Déclaration FCC l’arrêt incorrect des
points d’accès installés aux États-Unis qui sont
configurés sur des contrôleurs autres que le modèle
agréé aux États-Unis est considéré comme
contrevenant à l’homologation FCC. Toute violation
délibérée ou intentionnelle de cette condition peut
entraîner une injonction d’arrêt immédiat de son
utilisation par la FCC et peut déboucher sur la
confiscation de l’équipement (47 CFR 1.80).