Expanded operating temperature
Table 29. Expanded operating temperature specifications
Expanded operating temperature
Specifications
< 10% of annual operating hours
5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to
35°C), the system can operate continuously in temperatures as low
as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, de-rate maximum allowable dry
bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours
–5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to
35°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD panel and
in the System Event Log.
Video specifications
Table 30. R940 video specifications
Resolution
Refresh rate
Horizontal frequency
Pixel clock
1024 x 768
60 Hz
48.4 kHz
65.0 MHz
1280 x 800
60 Hz
49.7 kHz
83.5 MHz
1280 x 1024
60 Hz
64.0 kHz
108.0 MHz
1360 x 768
60 Hz
47.71 kHz
85.5 M
1440 x 900
60 Hz
55.9 kHz
106.5 MHz
1600 x 900
60 Hz (RB)
55.54 kHz
97.75 M
1600 x 1200
60 Hz
75.0 kHz
162.0 MHz
1680 x 1050
60 Hz (RB)
64.7 kHz
119.0 MHz
1920 x 1080
60 Hz
67.158 kHz
173.0 MHz
1920 x 1200 60
60 Hz
74.556 kHz
193.25 MHz
*RB-Reduced Blanking for Digital Displays requiring less blank time. This was introduced for Signal Integrity improvements by reducing Pixel
Clock rates for VGA-Analog input devices.
44
Appendix A. Additional specifications