Table 30. Configuration 9: R1A+R4C+R4D (continued)
Card type
Supplier
Category
Card Priority
Slot Priority
Bracket Height
Allowed
Max # of
Cards
CRD,NTWK,INT
L,FH,25G,4P,S2
8
Intel
NIC: 25Gb
5500
2, 1
FH
2
CRD,NTWK,BC
ME,FH,10G,4P,B
T
Broadcom
NIC: 10Gb
10800
2, 1
FH
2
CRD,NTWK,BC
ME,LP,10G,4P,B
T
Broadcom
NIC: 10Gb
10900
Not supported
LP
0
CRD,NTWK,INT
L,OCP3,25G,4P,
S28
Intel
OCP: 25Gb
13100
INT
OCP3
1
Removing the expansion card risers
Prerequisites
1. Follow the safety guidelines listed in the
.
2. Follow the procedure listed in the
Before working inside your system
3. Disconnect any cables that are connected to the expansion card.
Steps
1. For Riser 1, press the blue tab and holding the edges lift the expansion card riser from the riser connector on the system
board.
Figure 80. Removing the expansion card riser (Riser 1)
2. For Riser 2 and liquid cooling Riser 2, press the blue button on the riser, and holding the touch points lift the expansion card
riser from the riser connector on the system board.
NOTE:
The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
102
Installing and removing system components