●
If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to
the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the
iDRAC User’s Guide
available at
.
Removing a power supply unit blank
Prerequisites
Follow the safety guidelines listed in the
.
Steps
Pull the blank out of the system.
CAUTION:
To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a
non-redundant configuration. Remove the PSU blank only if you are installing a second PSU.
Figure 90. Removing a power supply unit blank
Next steps
Replace the
.
Installing a power supply unit blank
Prerequisites
1. Follow the safety guidelines listed in the
.
NOTE:
Install the power supply unit (PSU) blank only in the second PSU bay.
2.
Steps
Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.
Installing and removing system components
89