Table 19 Standby node cabling instructions (continued)
String
(Loop)
I/O - Port
Shelf Port
Length
3
I/O 6 - Port 0
B controller EXPANSION
port of the highest
number shelf in V3
2M
4
I/O 3 - Port 3
A controller EXPANSION
port of shelf V4.1
3M
4
I/O 2 - Port 2
B controller EXPANSION
port of the highest
number shelf in V4
3M
5
I/O 3 - Port 2
A controller EXPANSION
port of shelf V5.1
3M
5
I/O 6 - Port 2
B controller EXPANSION
port of the highest
number shelf in V5
3M
6
I/O 2 - Port 3
A controller EXPANSION
port of shelf V6.1
3M
6
I/O 6 - Port 3
B controller EXPANSION
port of the highest
number shelf in V6
3M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on
62
Data Domain DD9500 and DD9800 Systems
6.1