Installing Power Supply Units
|
33
WARNING:
Building Supply Notice: This product relies on the building's installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC,
10A international) is used on the phase conductors (all current-carrying conductors)
.
ATTENTION:
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de
l'installation électrique du local. Vérifier qu'un fusible ou qu'un disjoncteur de 120 V alt., 15 A U.S. maximum
(240 V alt., 10 A international) est utilisé sur les conducteurs de phase (conducteurs de charge).
WARNUNG:
Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß- bzw.
Überstromschutz installiert ist. Stellen Sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehr
als 240 V Wechselstrom, 10 A (bzw. in den USA 120 V Wechselstrom, 15 A) an den Phasenleitern (allen
stromführenden Leitern) verwendet wird.
You can install any power supply into any power supply slot. Dell Networking recommends installing
power supplies starting from the left side, top row of the chassis, leaving no blank slots between units.
To install an AC power supply:
Removing AC Power Supply Units
NOTE:
Do not remove a panel blank unless you are ready to install a power supply into that slot. After
removing a power supply, immediately place a panel blank in the empty slot. Blanks are required to control
airflow and electromagnetic interference.
A power supply failure is recognized by a red power LED, a lit RPM alarm LED, and, if configured, an
SNMP trap. If you are operating your C7004/C150 chassis with a redundant power supply, you can
install, remove, or replace a power supply without affecting system operation. If you are operating your
C7004/C150 system with only one power supply, you must completely power off the system to replace a
power supply
NOTE:
If a power supply fails, the entire unit must be replaced. There are no field serviceable parts inside the
unit.
.To remove an AC power supply:
Step
Task
1
Verify the switch is in the
OFF
(left)
position.
2
Secure the retaining latch in the unlatched position by tightening the screw into the threaded hole (
).
3
Slide the power supply into the top left-most power supply slot. See
for the correct orientation.
4
Plug the AC power cord into the power receptacle in the face of the power supply. See
for the location
of the receptacle.
5
Lower the retaining latch, and tighten it into place (
).
6
Plug the power cord into an AC power outlet.
Step
Task
1
Toggle the switch on the power supply to the
OFF
(left) position.
2
Disconnect the AC power cable from the AC power source and the front of the power supply.
3
Unscrew the retaining latch screw. Lift the latch, and secure it in the unlatched position by tightening the latch screw
(
).
4
Pull the power supply out of the slot using the handle.
Summary of Contents for C7004/C150
Page 1: ...Installing and Maintaining the C7004 C150 System ...
Page 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 14: ...14 Preparing the Site w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 18: ...18 Installing the C7004 C150 Chassis w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 28: ...28 Management Cable Pinout w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 40: ...40 Installing DC Power Entry Modules w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 44: ...44 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 61: ...System Specifications 61 Figure B 2 Chassis Dimensions Depth 15 5 inches ...
Page 70: ...70 Contacting Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 71: ......
Page 72: ...w w w d ell com support dell com Printed in the U S A ...