8
Installing the Hardware
Installing Power Modules
CAUTION: Do not install the Power Supply 1200W-AC and Power Supply
1600W-AC in the same chassis. The line cards will power down and data may
be lost.
If there is a failure in the power supply, you must replace it. Power supplies are
not field serviceable.
The C7004/C150 has six power supply slots at the front-bottom of the chassis.
The C7008/C300 has eight power supply slots at the front-bottom of the chassis.
The slots accept either the 1200W or 1600W AC power supply units (PSUs).
AC Power Supplies
•
There are two types of power supplies: Power Supply 1200W-AC and Power
Supply 1600W-AC. The minimum and redundant power supplies required to
operate are listed in the table below. Dell Networking recommends the
redundancy configuration.
•
The following table lists the PSU requirements for Dell Networking OS
version 8.4.5.0 or prior. 1600W-AC PSU is recognized by version 8.4.5.0 or
later.
Voltage Minimum
PSUs
Minimum with
Redundant
PSUs
C7004/C150
Power Supply 1200W-
AC/Power Supply
1600W-AC
100-120 Configuration
Dependent
Configuration
Dependent
200-240 Configuration
Dependent
Configuration
Dependent
C7008/C300
Power Supply 1200W-
AC/Power Supply
1600W-AC
100-120 Configuration
Dependent
Configuration
Dependent
Power Supply 1200W-AC 200-240 Configuration
Dependent
Configuration
Dependent
Power Supply 1600W-AC 200-240 Configuration
Dependent
Configuration
Dependent