background image

Upgrade Dell EMC Networking N1500 Series Switches  

 

 

 

Page 12

 

 

 

Boot Main Menu 

============== 

    1 - Start Operational Code 

    2 - Select Baud Rate 

    3 - Retrieve Logs 

    4 - Load New Operational Code 

    5 - Display Operational Code Details 

    9 - Reboot 

   10 - Restore Configuration to Factory Defaults 

   11 - Activate Backup Image 

   12 - Start Password Recovery

 

 

4.

 

Download the firmware to the switch using TFTP (Select option 

4 - Load new operational code). 

Skip this step 

if firmware is already loaded on switch.

 

 

Boot Main Menu 

============== 

1 - Start Operational Code 

2 - Select Baud Rate 

3 - Retrieve Logs 

4 - Load New Operational Code 

5 - Display Operational Code Details 

9 - Reboot 

10 - Restore Configuration to Factory Defaults 

11 - Activate Backup Image 

12 - Start Password Recovery 

Enter Choice# 4 

Creating tmpfs filesystem on /mnt/download for download...done. 

Current Active Image# /dev/mtd7 

Which Image to Update Active (/dev/mtd7) OR Back-Up (/dev/mtd6)? Select (A/B): A 

You selected to update Active Image /dev/mtd7... 

Select Mode of Transfer (Press T/X/Y/Z for TFTP/XMODEM/YMODEM/ZMODEM) []:T

 

 

Please ensure TFTP server is running to begin Transfer... 

Enter Server IP []:

10.10.10.200

 

Enter Host IP []:10.10.10.224 

Enter Host Subnet Mask [255.255.255.0]:255.255.0.0 

Enter Gateway IP []:10.10.10.254 

Enter Filename []:N1500v6.5.2.9.stk 

Do you want to continue? Press(Y/N):  y 

Bringing up eth0 interface...done. 
Adding default gateway 10.10.10.254 to the Routing Table...done. 

Erasing /dev/mtd7!!! 

Erasing 128 Kibyte @ 17e0000 -- 99 % complete. 

Updating code file...done. 

Code Update Instructions Found! 

Critical components modified on Active Partition -- System Reboot Recommended! 

 

Reboot? (Y/N): y 

  Rebooting... 

starting pid 11 
syncing filesystems....This may take a few moments 
Rebooting system! 

Reference platform resetting ...  
starting pid 17Rebooting system! 

Summary of Contents for 3WY51

Page 1: ... of Dell Inc Intel and Pentium are registered trademarks and Celeron is a trademark of Intel Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation Other trademarks and trade names may be used in this document to refer to either the entity claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other tha...

Page 2: ...verview 1 Upgrade Dell EMC Networking N1500 Series Switches 2 How to Access Serial Console on Dell EMC Networking N1500 Series switches 3 Upgrade Example of Dell EMC Networking N1500 Series Switches 3 Upgrade Stack of Dell EMC Networking N1500 Series Switches 9 Switch Recovery Procedure 11 Switch Recovery Example 11 End of document 15 ...

Page 3: ...ire stack will be required to run 6 3 2 4 or later 6 5 2 9 The show version CLI command will help to identify the Switch Hardware version of the switch Firmware Downgrade Overview Dell Networking N1500 series switches support firmware downgrade from 6 5 2 9 to an earlier 6 x x x release But migration of switch configuration information from a later release to an earlier release is NOT supported It...

Page 4: ...password in current configuration If not configured follow steps below to configure an enable password console configure console config enable password password console config exit console copy running config startup config 3 Download the 6 5 2 9 firmware image N1500v6 5 2 9 stk to the switch or stack master NOTE Activate the image to use as the boot active image after the switch resets Images on ...

Page 5: ...n the N1500 switches DNS is enabled but no DNS servers are configured If you assign an IP address to VLAN 1 you can connect to the switch management interface by using any of the front panel switch ports This is required to manage the N1500 switches over an Ethernet port Upgrade Example of Dell EMC Networking N1500 Series Switches This example shows an annotated upgrade example for a N1548 switch ...

Page 6: ...0002LF Manufacturer 0xbc00 Burned In MAC Address 001E C9E5 BD0F System Object ID 1 3 6 1 4 1 674 10895 3066 SOC Version BCM56150_A0 HW Version 1 CPLD Version 16 unit active backup current active next active 1 6 3 3 14 6 5 2 9 6 3 3 14 6 3 3 14 NOTE Set the image to use as the boot active image after the switch resets Images on the N1500 series switches are named active and backup 4 Activate the 6 ...

Page 7: ...ses Requesting system reboot U Boot 2012 10 00244 g9552470cd8 Feb 20 2018 15 54 29 I2C ready BENCH SCREENING TEST1 IPROC_XGPLL_CTRL_3 0x05400000 IPROC_XGPLL_STATUS 0x80000490 DCO code 73 DEV ID 0xdb56 SKU ID 0xb150 DDR type DDR3 MEMC 0 DDR speed 667MHz PHY revision version 0x00024006 ddr_init2 Calling soc_ddr40_set_shmoo_dram_config ddr_init2 Calling soc_ddr40_phy_calibrate C01 Check Power Up Rese...

Page 8: ...0x1 bank 0x0 reg 0x0 data 0x2100 bcmiproc_eth 0 relocate address 0xdff7c000 offset 0xc1f7c000 boot in 3 s Creating 1 MTD partitions on nand0 0x000000200000 0x000007000000 mtd 4 UBI attaching mtd1 to ubi0 UBI physical eraseblock size 131072 bytes 128 KiB UBI logical eraseblock size 126976 bytes UBI smallest flash I O unit 2048 UBI VID header offset 2048 aligned 2048 UBI data offset 4096 1 ecc_error...

Page 9: ...nboot 512k nenv 256k vpd 256k shmoo 112640k fs 16384k diags ubi mtd fs ethaddr 00 1e c9 e5 bd 10 quiet Starting kernel starting pid 1087 tty etc init d rcS starting pid 1217 tty dev ttyS0 etc rc d rc fastpath Mounting dev mtdblock4 at mnt fastpath done Mounting tmpfs at mnt application done Dell Networking Boot Options Select a menu option within 3 seconds or the Operational Code will start automa...

Page 10: ...l EMC Networking N1524 Serial Number 14C24M0030LF Manufacturer 0xbc00 Burned In MAC Address 001E C9E5 BA2F System Object ID 1 3 6 1 4 1 674 10895 3063 SOC Version BCM56150_A0 HW Version 1 CPLD Version 16 Image File N1500v6 5 2 9 Software Capability Stack Limit 4 VLAN Limit 512 unit active backup current active next active 1 6 5 2 9 6 3 3 14 6 5 2 9 6 5 2 9 8 Switch is now ready for normal operatio...

Page 11: ... 6 5 2 9 6 3 3 14 6 3 3 14 2 6 3 3 14 6 5 2 9 6 3 3 14 6 3 3 14 3 6 3 3 14 6 5 2 9 6 3 3 14 6 3 3 14 4 6 3 3 14 6 5 2 9 6 3 3 14 6 3 3 14 console boot system backup Activating image backup console show version System Model ID N1548P Machine Type Dell Networking N1548P Serial Number 15114M0002LF Manufacturer 0xbc00 Burned In MAC Address 001E C9E5 BD0F System Object ID 1 3 6 1 4 1 674 10895 3066 SOC...

Page 12: ...ion 16 Image File N1500v6 5 2 9 Software Capability Stack Limit 4 VLAN Limit 512 unit active backup current active next active 1 6 5 2 9 6 3 3 14 6 5 2 9 6 5 2 9 2 6 5 2 9 6 3 3 14 6 5 2 9 6 5 2 9 3 6 5 2 9 6 3 3 14 6 5 2 9 6 5 2 9 4 6 5 2 9 6 3 3 14 6 5 2 9 6 5 2 9 Update boot code via update bootcode command from stack master CLI and then perform stack reload for the new boot code to take effect...

Page 13: ...g If the boot menu does not appear after power cycling the switch check the serial port settings and the serial cable connections Make sure that RTS CTS HW flow control and XON XOFF SW flow control are disabled on the terminal It is preferred to use the serial cable supplied with the switch If you do not have the original serial cable it may be necessary to use a NULL modem device to access the sw...

Page 14: ...wnload for download done Current Active Image dev mtd7 Which Image to Update Active dev mtd7 OR Back Up dev mtd6 Select A B A You selected to update Active Image dev mtd7 Select Mode of Transfer Press T X Y Z for TFTP XMODEM YMODEM ZMODEM T Please ensure TFTP server is running to begin Transfer Enter Server IP 10 10 10 200 Enter Host IP 10 10 10 224 Enter Host Subnet Mask 255 255 255 0 255 255 0 0...

Page 15: ...up DISABLE all Virtual VTT C06 DDR40_PHY_DDR3_MISC C07 VDL Calibration C07 1 C07 2 C07 4 C07 4 1 C07 4 4 VDL calibration result 0x30000003 cal_steps 0 C07 4 5 C07 4 6 C07 5 C08 DDR40_PHY_DDR3_MISC Start DDR40_PHY_RDLY_ODT C09 Start ddr40_phy_autoidle_on MEM_SYS_PARAM_PHY_AUTO_IDLE C10 Wait for Phy ReadyDone DDR phy calibration passed Programming controller register ddr_init2 MemC initialization co...

Page 16: ...number of bad PEBs 0 UBI max allowed volumes 128 UBI wear leveling threshold 4096 UBI number of internal volumes 1 UBI number of user volumes 1 UBI available PEBs 8 UBI total number of reserved PEBs 872 UBI number of PEBs reserved for bad PEB handling 8 UBI max mean erase counter 37 16 UBIFS recovery needed UBIFS recovery deferred UBIFS mounted UBI device 0 volume 0 name fs UBIFS mounted read only...

Page 17: ...p BCM56150_A0 Driver BCM56150_A0 PCI unit 1 Dev 0xb150 Rev 0x01 Chip BCM56150_A0 Driver BCM56150_A0 SOC unit 0 attached to PCI device BCM56150_A0 SOC unit 1 attached to PCI device BCM56150_A0 186 Aug 21 02 06 43 0 0 0 0 1 General fp_main_task bootos c 195 8 Event 0xaaaaaaaa started 185 Aug 21 02 06 43 0 0 0 0 1 SIM Cnfgr_Thread sim_util c 3786 9 Switch was reset due to operator intervention Unit 1...