Specifications
This section lists the VEP4600 specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 0°C to 45°C (32°F to 113°F).
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only
with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
NOTE:
Restricted Material Compliance
.
Topics:
•
•
VEP4600 Expansion Card antennas
•
Chassis physical design
Table 1. Chassis physical design
Parameter
Specifications
Height
1.72 inches (43.6 mm)
Width
17.1 inches (434 mm)
Depth
15 inches (381 mm)
PSU/fan tray handle: 1.57 inches (40 mm)
Chassis weight with factory-installed components
16.40lbs (7.43 kg), (2 PSUs, and 5 fans, 1 rNDC card)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 2. Environmental parameters
Parameter
Specifications
Operating temperature
0°C to 45°C (32°F to 113°F) continuously
NOTE:
Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature
–40°F to 70°C (–40°F to 158°F)
Storage humidity
5% to 95%, non-condensing
Maximum thermal output
311W = 1061 BTU/hr
Maximum operational altitude
10,000 feet (3,048 meters)
Maximum non-operational altitude
39,370 feet (12,000 meters)
Shock
SV0115 — ODM
4
Specifications