Chapter V Functional Parameters Table
Page 25
Functional
Code
Name
Given Range
Factory Default
Modification
Restrictions
F28.16
CVT voltage
0-1000V
0
☆
F28.17
Voltage of
debugging mode
0-1000V
0
☆
F28.18
Rated power of
motor
/
Model
●
F28.19
Rated voltage of
motor
/
Model
●
F28.20
Rated current of
motor
/
Model
●
F28.21
Rated speed of
motor
/
Model
●
F28.22
Instant recovery
0. No action;
1. Recover to the
default.
0
★
F28.24
Acceleration time
/
15
☆
F28.25
Deceleration time
/
10
☆
F28.26
Timing function
0-65535h
0
☆
F28.27
Password protection 0-65535
0
☆
F28.28
Inversion
temperature
/
/
●
F28.29
Frequency reduction
temperature
0-95
℃
82
☆
F28.30
Under-load
protection
0: No protection;
1. Start protection.
0
☆
F28.31
Under-load current
0-6553.5A
Model
☆
F28.32
Under-load time
0-6553.5S
60
☆
F28.33
Under-load reset
0-6553.5S
600
☆
F28.39
Single phase mode
0. No start;
1. Start.
0
★
F28.40
Power down and
frequency reduction
0. No start;
1. Start.
0
☆
F28.41
Frequency decrease
rate
0-50.00Hz
3
☆
F28.42
The last failure
/
/
●
F28.43
The second to last
failure
/
/
●
F28.44
The third to last
failure
/
/
●
F28.45
The fourth to last
failure
/
/
●
F28.46
The fifth to last
failure
/
/
●
F28.49
Power setting
0.4-185.0kW
Model
●