BI51 Type User Manual V2.4
19
Calibration interface—Click
“
Calibration
”
to enter calibration interface
Calibration interface—Function area of BMS parameter configuration, users can configure
parameters and simulated failure on this interface.
a) Function area: click the button to enter the corresponding parameter configuration interface
b) Parameter configuration interface: system supports manually modification and batch import
parameters.
c) Import—Import the current parameters (“.json”) to BMS, click Calibration, and then click
Flash.
d) Export—Export the BMS data to a “,json” file, it can be used to modify batched parameters.
e) Read—Read the BMS existing parameters. Default: automatic reading.
f) Calibration—It’s necessary to click “Flash” after modifying the parameters. Otherwise, the
new parameters are invalid.
g) Flash—Insure to click “Flash” after calibrating parameters. Otherwise, parameters will reset
to the parameter after BMS restart.
h) Parameters display and modifying. Double click the data, and modify it.
i) eg: modifying the SCO to 30%, double click “65535”
→
enter 30
→
click “calibration”
→
click
“flash”.
4.2 Upgrade the software
Open Upper computer software, click”Upgrade”
→
click “Burn”
→
choose the program
→
click “Open”