BI51 Type User Manual V2.4
18
a) Upper computer function buttons: Overview / Cell information/ Calibration /Upgrade
b) BMS power and charger information
KeyOn means the power is from DC-DC converter during discharging.
Wakeup voltage means the power is from charger auxiliary power supply during charging.
The voltage of VCC should be equal to Keyon voltage and Wakeup voltage. Please contact
us if the voltage difference over 3V.
Charger output voltage/current: BMS get the charging data sent by charger (through CAN-
bus). The data should be same to charger display.
c) Alarm status
,
Green---Normal; Orange—Alarm; Red ---Major fault
4.1.2Cell information
Click “Cell information” to enter the batteries information interface.
Cell information interface— display cell voltage and temperature information.