Delfin ElastiMeter User Manual Download Page 18

ElastiMeter User Manual version 1.6 

15.8.2018

 

 

 

17 

A

PPENDIX 

A

PPENDIX 

C:

 

G

UARANTEE

 

G

UARANTEE

 

 

The ElastiMeter comes with a two (2) year guarantee from the date of purchase 

from  Delfin  Technologies  Ltd  or  an  authorized  distributor.  During  the 

guarantee period a faulty device will be repaired or replaced free of charge by 

Delfin  Technologies  Ltd.  The  guarantee  covers  raw  materials  and 

manufacturing faults. Batteries are excluded from this guarantee.  

 

In  order  to  obtain  service  under  this  guarantee,  customer  must  notify  Delfin 

Technologies of the defect before the expiration of the guarantee period and 

make suitable arrangements for the performance of service. Customer shall be 

responsible  for  packaging  and  shipping  the  defective  product  to  a  location 

designated by Delfin Technologies, transportation charges prepaid, and with a 

copy of customer proof of purchase. 

 

This  guarantee  shall  not  apply  to  any  defect,  failure  or  damage  caused  by 

improper use or inadequate maintenance and care. Delfin Technologies shall 

not  be  obligated  to  furnish  service  under  this  guarantee  1)  to  repair  damage 

resulting  from  attempts  by  personnel  other  than  Delfin  Technologies 

representatives  to  repair  or  service  the  product;  2)  to  repair  any  damage  or 

malfunction  caused  by  the  use  of  non-Delfin  Technologies  supplies;  3)  to 

service a product that has been modified or integrated with other products when 

the effect of such modification or integration increases the time or difficulty of 

servicing the product. 

 

NOTHING IN THIS GUARANTEE SHALL BE CONSTRUED AS A GUARANTEE FOR 

MERCHANTABILITY  OR  FITNESS  FOR  ANY  SPECIFIC  USE  OR  PURPOSE,  AND 

THIS  GUARANTEE  IS  LIEU  OF  ALL  OTHER  GUARANTEES,  EXPRESS  OR 

IMPLIED. DELFIN TECHNOLOGIES SHALL NOT BE HELD  LIABLE UNDER THE 

TERMS OF THIS GUARANTEE FOR ANY SPECIAL, INDIRECT, INCIDENTIAL OR 

CONSEQUENTIAL  DAMAGES  CLAIMED  IN  CONNECTION  WITH  THE 

ELASTIMETER’S PERFORMANCE OR AVAILABILITY. 

 

Delfin Technologies Ltd 

P.O. Box 1199 (Microkatu 1)  

70211 Kuopio, FINLAND 

Summary of Contents for ElastiMeter

Page 1: ...www delfintech com ElastiMeter User Manual...

Page 2: ...FACE DESCRIPTION 4 OPERATING INSTRUCTIONS 5 ADJUSTING SETTINGS 7 RECOMMENDATIONS FOR MEASURING WITH THE ELASTIMETER 8 MAINTENANCE CLEANING AND DISINFECTING 9 CALIBRATION 10 TECHNICAL DATA 11 APPENDIX...

Page 3: ...2...

Page 4: ...and thus the skin s response under a short term load indicates its instant elastic properties APPLICATIONS Instant skin elasticity measurements give important information on the biophysical propertie...

Page 5: ...indicator 3 Battery voltage indicator 4 Display 5 Number of the sample 6 Instant skin elasticity ISE value 7 Past values ElastiMeter Accessories available ElastiMeter measuring unit DMC data collectio...

Page 6: ...5 seconds o The indenter touches the skin first then the base plate o The indenter imposes a constant deformation when the base plate is in full contact with the skin o The force sensors recognize the...

Page 7: ...ISE reading is the mean of 5 consecutive measurements Readings under the recent value are means of previous measurements If the probe is left on the skin for too long the message OFF SKIN is displayed...

Page 8: ...stiMeter on by pressing the operating button briefly 2 When the device is on press the button again and hold it until the MENU is displayed Then release 3 The indicator starts to scroll downwards thro...

Page 9: ...o Avoid skin sites over superficial bones tendons and large veins Environmental conditions The ElastiMeter can be used in normal room temperature Recommended operating conditions are mentioned in the...

Page 10: ...d with ethanol Set the moistened soft paper on the table and wipe the measurement probe slightly to the paper Use only soft paper tissue with no lint The probe head must be completely dry before use N...

Page 11: ...Do not use rechargeable batteries 4 Replace and screw the bottom cover in place Do not touch the circuit board with any object CALIBRATION Delfin ElastiMeter is recommended to be calibrated every oth...

Page 12: ...x 45 x 35 mm o Weight with batteries 153 g o Protection class IP52 o Measurement completion time ISE 0 5 seconds o Measurement repeat cycle ISE 10 measurements per minute typically o Measured paramet...

Page 13: ...Storage at temperature 5 C to 35 C o Storage at relative humidity 5 to 80 Warranty o Limited two year warranty see Appendix C Bluetooth module certifications o Contains FCC ID QOQBLE113 o Contains IC...

Page 14: ...s not correct or the probe is left on the skin for too long LO FORCE Applied contact force too low HI FORCE Applied contact force too high OK FORCE Applied contact force correct LO SPEED Skin contact...

Page 15: ......

Page 16: ...contact Make sure the measuring surface base plate is fully and evenly in contact with the skin Make sure your hand is supported during the measurement and the base plate touches the skin perpendicula...

Page 17: ......

Page 18: ...not apply to any defect failure or damage caused by improper use or inadequate maintenance and care Delfin Technologies shall not be obligated to furnish service under this guarantee 1 to repair dama...

Page 19: ...Delfin Technologies Ltd info delfintech com www delfintech com...

Reviews: