Versa Drawer™ Refrigeration Units 

Delfield ·  980 S. Isabella Road, Mt. Pleasant, MI 48858 ·  (989) 773-7981 or (800) 733-8829 ·  Fax (989) 773-3210 

OPERATION

GENERAL

Each drawer operates independently in one of four 

modes at any time:

Refrigerator mode 

 The drawer operates at a set 

point of 37°F (3°C), maintaining a range between 34°F 

(1°C) and 40°F (4°C).

Freezer mode 

 The drawer operates at a set point of 

-3°F (-19°C), maintaining a range between -6°F 

(-21°C) and 0°F (-17°C). 

Thaw Cabinet mode 

 The drawer maintains 

temperature  between 36°F (2°C) and 41°F (5°C) 

for a minimum of 4 hours or longer if required. Once 

the thaw cycle is complete, the drawer mode is 

automatically changed to refrigerator mode.

Convenience Chiller mode 

 The drawer operates as 

a chiller, maintaining the convenience chiller set point 

of 23˚F (-5˚C) for four hours. Once the convenience 

chiller cycle is complete, the drawer mode is changed 

to refrigerator mode.
Drawer gaskets are magnetic and mount to the drawer, 

snapping in place and are removable without tools.

REFRIGERATION SYSTEM

In a 4-drawer system there are two compressors; 

one operating drawers 1 and 2 and one operating 

drawers 3 and 4. In a 2-drawer system there is a single 

compressor.

TEMPERATURE MONITORING

Temperature sensors are located in each drawer. The 

drawer temperatures are displayed on the control 

panel.

CONTROL PANEL

The control panel provides information indicating the 

current mode of each individual drawer. In addition, 

the actual temperature of the drawer is displayed.  See 

page 7 for control panel operation

DEFROST

An automatic defrost occurs every six hours in  

refrigerator and freezer mode.   

Chiller product Info

Note:  These results are based on chilling at a cabinet 

temperature of 5˚F(-15˚C) and 10 pounds(4.5kg) 

of product per drawer.  The times are based on the 

duration to go from 140˚F(60˚C) to 40˚F(4˚C).  The 

maximum limit of product to be chilled is no more than 

10 pounds(4.5kg), not including pans.  Product should 

be covered and no more than 2"(5cm) deep in the pan.

Product

Chill Time

Mash Potatoes

3 hours 21 minutes

Scrambled Eggs

1 hour 53 minutes

Green Beans

2 hour 49 minutes

Soup (Vegetable)

2 hour 58 

Spaghetti with Meat sauce

2 hours 32 minutes

Summary of Contents for Versa Drawer 18600VD

Page 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Page 2: ......

Page 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Page 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Page 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Page 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Page 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Page 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Page 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Page 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Page 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Page 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Page 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Page 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Page 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Page 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Page 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Page 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Page 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Page 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Page 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Page 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Page 23: ......

Page 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...

Reviews: