background image

12

Versa Drawer™ Refrigeration Units 

Delfield ·  980 S. Isabella Road, Mt. Pleasant, MI 48858 ·  (989) 773-7981 or (800) 733-8829 ·  Fax (989) 773-3210 

2-Drawer Wiring Schematic

G

L1

I/O BO

ARD

DISPL

AY BO

ARD

DET

AILS

FOR PIN C

ONNECTION

SEE BO

ARD C

ONNECT

OR

I/O BO

ARD

VAL

VES

VAL

VES

J31

1

4

J22

1

J23

J19

J18

1

J11

C

OIL

D4

B

OX

D3

C

OIL

J8

C

OIL

B

OX

D2

J6

C

OIL

D1

J7

J4

J2

J3

B

OX

J5

B

OX

J1

C

OND F

AN

D3 & D4

D1 & D2

1

J27

1

J28

1

2

J32

J33

A

C HO

T

SP1

SP2

C

OND 1

C

OND 2

J24

J25

C

OMP 1

1

J11

J26

C

OMP 2

1

J34

J35

J36

J9

J10

B

OX

B

OX

C

OIL

C

OIL

1

J30

1

J29

J29

1

1

J31

2-D1 SWIT

CH

4- C

OMMON FOR D3 AND D4 DOOR SWIT

CHES

3-D2 SWIT

CH

1- C

OMMON FOR D1 AND D2 DR

W SWIT

CHES

5-D3 SWIT

CH

6-D4 SWIT

CH

2-NC

2-NC

J29

1

J30

J27

1

J27

D1 & D2 V

AL

VES

3-D4 FR

AME HEA

TER

4-D2 HO

T GAS SOLENOID

1-D1 REFG SOLENOID

2-D1 HO

T GAS SOLENOID

3-D2 REFG SOLENOID

1-D1 FR

AME HEA

TER

3-D2 FR

AME HEA

TER

1-D3 FR

AME HEA

TER

2-D3 HO

T GAS SOLENOID

3-D4 REFG SOLENOID

4-D4 HO

T GAS SOLENOID

1-D3 REFG SOLENOID

J28

PO

WER T

1 T

O 1

1-+8V

I/O T

O DISP

.

2 T

O 2

2-GR

OUND

DISPL

AY BO

ARD

4

J22

1

1

J23

J19

J18

 50/60 HZ

85-265 V

A

C

C

ONTR

OL PO

WER

BO

ARD C

ONNECT

OR MAP

1

J28

D3 & D4 V

AL

VES

J33

J32

C

OND F

AN

2

1

SUCTION 

PRESSURE

TR

ANSDUCER

J24

A

C HO

T

1

J26

C

OMP 2

1

SP2

C

OIL

J34

2- SIGNAL

3- C

OMMON

J11

SP1

1- +5V

LO

ADS

J25

J25-A

C HO

FOR ALL A

C

C

OMP 1

1

J11

C

OIL

J8

D2

C

OIL

J6

J7

D1

B

OX

C

OIL

J36

B

OX

D4

C

OIL

J9

B

OX

D3

B

OX

J10

C

OIL

C

OND 1

J5

B

OX

B

OX

J1

J2

J3

J4

2 T

O 2

3 T

O 3

1 T

O 1

PAIR.

 1 AND 2 T

WISTED

,

3 SHIELD

.

TO DISPL

AY BO

ARD

C

OMMUNIC

ATION C

ABLE

 I/O T

O DISP

.

PREFER SHIELDED T

WISTED

TEMPER

ATURE SENSORS

J35

C

OND 2

4-+12V FOR D3 AND D4 F

ANS

1-+12V FOR D1 AND D2 F

ANS

3-D2 F

ANS RETURN

6-D4 F

ANS RETURN

5-D3 F

ANS RETURN

2-D1 F

ANS RETURN

12 VDC

SWIT

CH

EV

AP

. F

ANS

DR

A

WER LIMIT

HEA

TER

DR

A

WER FR

AME

BO

X 1

12 VDC

7

2

1

MTR

MTR

EV

AP

. F

ANS

8

SWIT

CH

34

HEA

TER

DR

A

WER FR

AME

DR

A

WER LIMIT

BO

X 2

1

MTR

MTR

PR

OBE

PR

OBE

BO

X TEMP

.

3

9

7

35

EV

AP

. TEMP

.

8

9

3

PR

OBE

BO

X TEMP

.

EV

AP

. TEMP

.

PR

OBE

34

1

7

35

16

12

11

15

11

REFG.

 

DR

A

WER T

WO

SOLENOID

HO

T GAS

12

REFG.

 

DR

A

WER ONE

SOLENOID

HO

T GAS

SOLENOID

1-+8V

PO

WER T

I/O BO

ARD

1 T

O 1

DISP

. T

O I/O

2 T

O 2

2-GR

OUND

1

J1

1

1

J2

C

ONTR

OL 

1 T

O 1

C

OMMUNIC

ATION C

ABLE

3 T

O 3

2 T

O 2

DISP

. T

O I/O

TO I/O BO

ARD

3 SHIELD

.

PAIR.

 1 AND 2 T

WISTED

,

PREFER SHIELDED T

WISTED

1

33

25

24

J18

J19

N

PO

WER

2

TWO DR

A

WER WIRING SCHEMA

TIC

15

16

33

C

OND

. F

AN

MTR

C

OMPRESSOR

MTR

25

TR

ANSDUCER

PRESSURE

NSK

C

OND

. IN

TEMP

. PR

OBE

TEMP

. PR

OBE

C

OND

. OUT

WHITE (

V

OUT

)

RED (

VDC IN)

BL

A

CK (C

OM)

SOLENOID

Summary of Contents for Versa Drawer 18600VD

Page 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Page 2: ......

Page 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Page 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Page 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Page 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Page 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Page 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Page 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Page 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Page 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Page 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Page 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Page 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Page 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Page 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Page 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Page 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Page 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Page 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Page 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Page 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Page 23: ......

Page 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...