background image

Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

2

Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual

3

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

RECEIVING AND INSPECTING UNIT.................................. 2
MECHANICAL DATA ............................................................. 3
INSTALLATION...................................................................... 4
MAINTENANCE .................................................................... 4
OPERATION.......................................................................... 5
SHELF INSTALLATION ......................................................... 6
DEFROST TIMER ................................................................. 7
REFRIGERATOR AND FREEZER WIRING DIAGRAMS...... 8
REPLACEMENT PARTS LIST.......................................... 9-11
STANDARD LABOR GUIDELINES ..................................... 12
STANDARD WARRANTIES............................................ 13-14
AUTHORIZED PARTS DEPOTS ......................... BACK PAGE

On refrigeration and freezer storage units, the serial tag is 
located on the upper left rear corner of the cabinet exterior. 

Always have the serial number of your unit available when 
calling for parts or service.  A complete list of authorized 
Delfield parts depots is shown on the back cover of this 
manual.

Copyright ©2003 The Delfield Company.  All rights reserved.  Reproduction 
without written permission is prohibited.   Vantage 6000™ Series and Vantage 
Merchandisers™, and Delfield are registered trademarks of The Delfield 
Company

Contents

Serial Number Location

Even though most equipment is shipped crated, care should 

be taken during unloading so the equipment is not damaged 

while being moved into the building.

1.  Visually inspect the exterior of the package and skid or  

container.  Any damage should be noted and reported to 

the delivering carrier immediately.

2.  If damaged, open and inspect the contents with the 

carrier.

3.  In the event that the exterior is not damaged, yet upon 

opening, there is concealed damage to the equipment 

notify the carrier.  Notification should be made verbally as 

well as in written form.

4.  Request an inspection by the shipping company of the 

damaged equipment.  This should be done within 10 days 

from receipt of the equipment.

5.  Check the lower portion of the unit to be sure legs or 

casters are not bent.

6.  Also open the compressor compartment housing and 

visually inspect the refrigeration package.  Be sure lines 

are secure and base is still intact.

7.  Freight carriers can supply the necessary damage forms 

upon request.

8.  Retain all crating material until an inspection has been 

made or waived.

Uncrating the Equipment

First cut and remove the banding from around the crate.  

Remove the front of the crate material, use of some tools will 

be required.  If the unit is on legs remove the top of the crate 

as well and lift the unit off the skid.  If the unit is on casters it 

can be "rolled" off the skid.

Receiving and Inspecting the Equipment

Summary of Contents for GFR1-G

Page 1: ...Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Effective Date March 2003 I...

Page 2: ...o the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrie...

Page 3: ...9 614 5 20P VFR3 G 2 115 7 8 11 0 63 41 0 9 1 3 1 2 3365 3551 150 24 854 2 5 15P REMOTE VRR1R G 115 4 0 20 12 1 3 1 5 820 2010 130 15 290 NA VRR2R G 115 5 0 43 26 6 6 1 4 1453 2898 150 19 444 NA VRR3R...

Page 4: ...he unit on the pallet until one of the sets of four holes for the casters legs are exposed Take the caster leg and align the holes on its mounting plates with the holes in the bottom of the unit Using...

Page 5: ...ng cycles with the compressor Defrost Cycle When defrost control goes into defrost power to the condensing unit and evaporator fans is interrupted and the defrost heater is energized The defrost heate...

Page 6: ...6000 Series and Glass Door Merchandisers Reach Ins Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 6 Shelf Installation 2 and 3 do...

Page 7: ...s follows Defrost Time Dip Switch Setting min off off off off void on off off off 5 off on off off 10 on on off off 15 on on off on 20 on off on off 25 off on on off 30 on on on off 35 off off off on...

Page 8: ...ED BALLAST FLUORSCENT LAMP HLS CONDENSATE HEATER L1 N G ENERGY SAVER SWITCH BLACK SOL SOLENOID VALVE DLFD DEFROST LIMIT FAN DELAY COND CONDENSING UNIT HLS HIGH LIMIT SAFETY DS DOOR SWITCH Display ligh...

Page 9: ...oor RH 000 AHA 020K Assy louver 3 dr 1701313 Door gasket 2162515 Fan motor 2193907 Lamp bulb 36 2193928 Lamp bulb 18 2193939 Lampholder LH 2193940 Lampholder RH 2194161 Ballast 2194224 Temp control 21...

Page 10: ...RH 3234641 Hinge bracket top 3234644 Caster 3234753 Door lock 3234754 Caster w brake 3516051 Accumulator 3516185 Guard fan 3516191 Filter dryer 3516309 Evap coil 1 dr 3516313 Thermometer 3526807 Cond...

Page 11: ...defrost limit 2194235 Heater safety switch 2194578 Ballast 2194590 Defrost heater 2194606 Rocker switch 2194619 Light socket 3233953 Hinge Top LT BTM RT 3234480 Bracket 1 2 dr RH 3234641 Hinge bracke...

Page 12: ...HOUR IS ALLOWED TO REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Therm...

Page 13: ...E CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the...

Page 14: ...ial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of me...

Page 15: ...Vantage 6000 Series and Glass Door Merchandisers Reach Ins Service and Installation Manual 15 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com NOTES...

Page 16: ...800 433 1804 toll free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 1...

Reviews: