14
Part Number: 9295040 07/17
Installation
Section 2
Door Sweep Adjustment
1. Verify unit is level with 4’ Level. Shim as needed.
2. Remove door sweep before making door adjustments.
3. Adjust doors hinges so door closes by itself.
• A properly adjusted door will close and seal when the
door is held open 3” or less with no assistance.
4. Reinstall door sweep. It may need to be reinstalled in
new holes so that it does not interfere with the door
closing.
• If it is too tight to ramp it will hold door open.
• Make sure sweep is just touching ramp when closed.
Sweep just touching
ramp
Unit
Ramp
Door
5. Verify once again that the door will close and seal when
held open 3” or less.
6. If this is a multi-section unit make sure door stays shut
or closes by itself when other doors are shut.
New Bottom Hinge Cartridge Installation
1. Install the new cartridge into the door as received. The
new cartridge will be in the CLOSED position.
2. As you unload the hinge tension be careful to hold on
tight because you should feel the strong spring tension
as you rotate the hinge. Place the hinge bracket on the
square hinge pin and rotate it ½ turn to the outside of
the door.
3. After the hinge has been rotated, it will now be in the
OPEN position and NOT under spring tension.
4. Mount the door back onto the cabinet with the door
OPEN. The door should now close properly.
5. Begin closing the door, the door should finish closing
on it’s own. If the door stays open remove the door and
hinge bracket.
6. Using the hinge bracket rotate the square peg on the
cartridge until you feel tension and resistance if you
move the hinge in either direction. The hinge is now in
the CLOSED position. Repeat instructions starting with
step 2.