The optional wall mount kit is designed to securely hold a 

7000 Series unit to a structurally sound wall. It meets the 

requirements as established by Underwriter’s Laboratories 

of withstanding a static load of four times the weight of the 

cabinet alone.

The Delfield Company cannot assume 

any responsibility for damage to a wall 

or injury of any persons should the wall 

fail as a result of the unit’s weight. Nor 

will The Delfield Company assume any 

responsibility for damage or injury as a 

result of the wall mount fixture failing if it is 

determined that the installation instructions 

were not properly followed.

List of materials

2 — 2" x 2" x 3/16" (5.1 cm x 5.1 cm x 0.2 cm) angled  

        aluminum brackets, 48" (121.9 cm) long
12 — #10 x 7/8" type A hex head metal screws
6 — 1/4" x 2–1/2" lag bolts
2 — stainless steel trim pieces

                        

1     Position the prepunched aluminum bracket 

on the top of the unit, flush with the back 

edge, and mark the location of the holes 

on the unit. There should be one hole 

approximately 5/8" (1.6 cm) from each end 

of the cabinet, and a third hole 8.75" (22.2 

cm) from the right end of the cabinet. Be 

sure to use the prepunched holes; screws 

in these locations tie into the internal 

support structure of the unit.

                      2     Drill 9/64" (3.6 mm) holes at the locations 

as marked. Attach the bracket to the unit 

with three of the #10 sheet metal screws.

                      3     Mount the bottom bracket to the wall.
On a stud wall, the bottom bracket should be screwed into a 

minimum of three studs with the provided 1/4" x 2–1/2" lag 

bolts. On a masonry block wall, the bottom bracket should be 

screwed into the wall at a minimum of three evenly spaced 

locations with 1/4" diameter toggle bolts (not provided).
When positioning the bottom bracket, be sure to allow at 

least 6" (15.2 cm) of clearance above and below the unit. Be 

sure the bottom bracket is level before continuing.

                        

4     Position the unit on the bottom bracket and 

attach the top bracket to the wall using the 

same method as in step 3.

                      5     Attach the bottom bracket to the unit using 

the prepunched holes and three of the #10 

sheet metal screws.

WALL MOUNT INSTALLATION

                      6     Attach the stainless steel trim strips to the 

left and right sides of the cabinet using 

three #10 metal screws on each side.

9000 Series

The Delfield Company cannot assume 

any responsibility for damage to a wall 

or injury of any persons should the wall 

fail as a result of the unit’s weight. Nor 

will The Delfield Company assume any 

responsibility for damage or injury as a 

result of the wall brackets failing if it is 

determined that the installation instructions 

were not properly followed.

When choosing a location to mount your 9000 Series display 

case, keep in mind that the entire unit must be removed from 

the wall in order to clean the condenser. This must be done 

on a regular basis, in most cases not longer than every three 

months. Install the equipment in a location that will allow 

easy removal for cleaning.

                         1     Two wall brackets are supplied with 36" and 48" 

long units; three brackets are supplied with 60" 

and 72" long units. Lag bolts are not supplied 

(see below for recommended sizes). Use all 

brackets provided for a secure installation.

On a stud wall, the brackets should be screwed into two 

studs with 1/4" lag bolts so that 2.50" (6.4 cm) of the lag 

bolt engages the stud. On a masonry block wall, the brackets 

should be screwed into the wall at two evenly spaced loca-

tions with 1/4" diameter toggle bolts.
When positioning the brackets, be sure to allow at least 6" 

(15.2 cm) of clearance above and below the unit.

                        

2     After the brackets are attached to the wall 

with one bolt in each, check that they are 

level. Finish mounting the brackets.

                      3     Once the brackets are secure, lift the unit 

into place and engage the angle bracket on 

the back of the unit into the wall brackets.

S

T P

E S

S

T P

E S

Summary of Contents for 7048-M

Page 1: ...stallation Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Model 724 7000 and 90...

Page 2: ...3 WALL MOUNT INSTALLATION 4 WIRING DIAGRAMS 5 OPERATION 6 MAINTENANCE 6 REPLACEMENT PARTS 7000 SERIES 7 MODEL 724 7 PIKE STYLE DOORS 8 9 9000 SERIES 10 TROUBLESHOOTING REFERENCE 11 STANDARD WARRANTIES...

Page 3: ...urce of intense heat such as ovens or ranges Do not install 9000 Series units closer than 6 15 2 cm from the ceiling or counter This will allow air flow to the machine compartment The 724 should be in...

Page 4: ...be sure to allow at least 6 15 2 cm of clearance above and below the unit Be sure the bottom bracket is level before continuing 4 Position the unit on the bottom bracket and attach the top bracket to...

Page 5: ...LACK WHITE CONDENSER FANS 2 on 9060 9072 EVAPORATOR FAN TEMPERATURE CONTROL LIGHT SWITCH LIGHT LIGHTS G COMPRESSOR WIRING DIAGRAM FOR 115V 60Hz 1 ph MODEL 724 POWER SWITCH BLACK WHITE CONDENSER FAN EV...

Page 6: ...l 724 units is easily removable for cleaning or replacement 1 Remove the screws that attach the perforated top to the unit 2 Lift off the perforated top and set it aside 3 Facing the front of the unit...

Page 7: ...HFC 404A The following replacement parts are for use with Model 724 units using HFC 404A refrigerant only Ballast 219 4161 Bracket assembly fan cond 033 0146 Capillary tubing 84 of 044 007 4100 Compr...

Page 8: ...embly 345 5454 1 Bearing roller single 2 per door 323 4636 2 Gasket bumper 15 1 8 323 3926 3 Gasket wiper strip 13 11 16 323 3934 4 Spring 23 green 323 3950 5 Track bottom 56 323 3908 6 Track top 57 3...

Page 9: ...Pike These doors allow simple cleaning and maintenance as well as easier replacement if the glass is cracked or broken Individual replacement parts for these Pike style doors are not stocked at the D...

Page 10: ...ke style complete 345 5454 X Door assembly Pike style complete 345 5455 X Fan blade condenser 351 6274 X X X X Fan blade evaporator 216 2500 X X X X Fan guard condenser 351 6178 X X X X Fan guard evap...

Page 11: ...Display Cases 724 7000 9000 Series Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com...

Page 12: ...to the extent of the original manufacturer s express warranty to Delfield Failure of the Original Purchaser to receive such manufacturer s express warranty to Delfield Failure of the Original Purchase...

Page 13: ...t to affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location w...

Page 14: ...Display Cases 724 7000 9000 Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 14 NOTES...

Page 15: ...depot 9 Global Parts and Supplies 10850 Sanden Drive Dallas TX 75238 1 800 442 5026 toll free 972 484 2954 local 214 340 2363 fax serves AR LA NM OK TX 7 GCS SERVICE 9923 S W 178th St Vashon WA 98070...

Reviews: