43
Programming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to
“08” (Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to
“16”.
Scan “1st Identified Character” and set the identified
position to “00”, then set the identified character to
“39” (Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code
symbology to
“
08
”
.
Scan 1st Insertion” and set the identified position to
“
06
”
, then inserted characters to
“
09
”
(Hex Code of
TAB),
“
53
”
(Hex Code of S),
“
4E
”
(Hex Code of N).
Scan “2nd Insertion” and set the identified position to
“
12
”
, then inserted character to
“
09
”
. In the final,
you must scan
“
FIN
”
(Finish) code to terminate this
selection.
Scan “3rd Insertion” and set the identified position to
“
16
”
, then inserted character to
“
09
”
. In the final,
you must scan
“
FIN
”
(Finish) code to terminate this
selection.
[Data Replacer]
Scan “Replacer Control” and set bar code symbology
to
“
08
”
.
Scan “1st Replacement” and set the identified
position to
“
00
”
, then replaced character to
“
41
”
(Hex Code of A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology
to
“
08
”
.
Scan “1st Organization” and set the identified
position to
“
16
”
, then set the data transmission to
“
0
”
(forward).
Scan “2nd Organization” and set the identified
position to
“
17
”
, then set the data transmission to
“
1
”
(backward).
Scan
“
END
”
(Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the
preset working flow as below:
Verifier
Formatter
Replacer
Organizer
So when you set the identified position in Data
Organizer, you must consider the inserted data which
you already set via Data Formatter.