DelfiScan C70 

Programming Manual 

 

 

Summary of Contents for DelfiScan C70

Page 1: ...1 DelfiScan C70 Programming Manual ...

Page 2: ...on 12 Symbology Reading Control 13 Keyboard Interface Control 26 Serial Interface Control 30 Wand Emulation Control 33 Operation Control 34 Condensed DataWizard 32 Appendix Keyboard Function Code Table 45 ASCII Input Shortcut 46 Host Interface Quick Set Operation Mode Quick Set 47 Option Codes 48 System Commands 49 Regulatory FCC part 15B EN55022 EN55024 EN61000 3 2 EN61000 3 3 CNS13438 Industry C...

Page 3: ...ket applications to unleash your productivity This document provides installation and programming instructions for DelfiScan Imagers C70 Series Connecting Disconnecting Cable DelfiScan imagers provide PS 2 DOS V Keyboard Wedge RS 232 Serial USB interfaces capability To disconnect the cable please straighten one end of a paper clip then insert it into the cable release hole and press in After that ...

Page 4: ...ability to connect different host devices by PS 2 DOS V Keyboard Wedge RS 232 Serial and USB interfaces Please choose one of the interface cables to connect your host device by referring to the illustrations below PS 2 DOS V Keyboard Wedge RS232 Serial USB ...

Page 5: ...family for multiple settings you need only turn over the programming page to find next desired programming family System Command The System Command is the highest level bar code command which directs DelfiScan to perform immediate operations such as entering programming mode PROGRAM exiting programming mode EXIT listing system information SYSLIST recovering to factory preset configurations M_DEFAU...

Page 6: ... Each kind of programming procedure is listed in the following pages for your reference Please give careful attention to become familiar with each programming procedure If the programming family must take multiple scans selection cycling scan selection or dual level selection procedures the family of the programming menu will be marked with the matched representing symbol of Programming Category P...

Page 7: ...ion number to host via selected host interface then issue the completion beeping Scan M_DEFAULT DelfiScan will recover all programmable parameters into factory preset configurations then issue the completion beeping Program End Please note that the DelfiScan will take 3 4 seconds to store parameters in internal Flash Memory ASIC or non volatile memory after you scan the END Please don t turn off t...

Page 8: ...of Family Codes Scan One of Option Codes Repeat Selection Scan END No Yes Enter programming mode Select one of desired programming families Select one option code of desired parameter Want to select another programming family Exit programming mode ...

Page 9: ... Select one or several option codes to select desired parameters 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode Scan PROGRAM Scan One of Family Codes Scan One or Several Option Codes Repeat Selection Scan END No Yes ...

Page 10: ...select one or several option codes of desired parameters as Single or Multiple scans selection Finish cycling selection If necessary Want to select another programming family Exit programming mode Scan PROGRAM Scan One of Family Codes Scan One of Option Codes Repeat Selection Scan END No Yes Scan FIN ...

Page 11: ...rameters 1 Select one or several option codes of desired parameters 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode Scan One of Family Codes 1st Scan Several Option Codes Yes Scan PROGRAM Repeat Selection Scan END No 2nd Scan One or Several Option Codes ...

Page 12: ...iMac IBM PS 55 5576 001 code set 81 keyboard wedge interface IBM PS 55 5576 002 code set 81 keyboard wedge interface IBM PS 55 5576 003 code set 81 keyboard wedge interface IBM PS 55 5576 A01 code set 1 keyboard wedge interface IBM PS 55 5576 001 code set 8A keyboard wedge interface IBM PS 55 5576 002 code set 8A keyboard wedge interface IBM PS 55 5576 003 code set 8A keyboard wedge interface IBM ...

Page 13: ...stal Code default L German Postal Code default M ATA default O Code 11 default P MSI Plessey default R UK Plessey default S Telepen default T 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character 1 character ...

Page 14: ... EAN 128 UPC A UPC E EAN CAN JAN 13 EAN CAN JAN 8 Codabar NW 7 Code 39 Code 32 HIBC Code 25 Family IATA Code 93 Code 11 MSI Plessey UK Plessey Telepen GS1 DataBar RSS 14 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 If your application is reading known limited bar code symbologies you may increase the reading speed and decrease the reading error possibility by selecting those known symbologies only...

Page 15: ...Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Code 39 Append Off Code 39 Append On 0 1 2 3 4 5 6 7 8 9 A B C Code 39 Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then DelfiScan will term...

Page 16: ...ol transmission Enable ABCD TN E start stop symbol transmission Enable abcd tn e start stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 A B C Codabar min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate th...

Page 17: ...ading 1 portion 0 1 2 3 4 5 6 7 8 9 A B UPC Supplement Setting SS SS SS SS SS SS SS SS Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2 5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On 0 1 2 3 4 5 6 ...

Page 18: ...on UPC EAN JAN CAN Basic Length Disable Check Digit Disable Numeric System With 2 digit Addendum With 5 digit Addendum Enable Standardization Enable Expansion UPC A 12 1 1 2 5 1 0 UPC E 7 1 1 2 5 1 5 EAN JAN CAN 13 13 1 NC 2 5 NC 0 EAN JAN CAN 8 8 1 NC 2 5 NC 5 ...

Page 19: ...s Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2 5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN JAN Addenda Separator Off EAN JAN Addenda Separator On 0 1 2 3 4 5 6 7 IATA Setting SS SS SS SS SS SS SS SS SS SS SS Select 15 digit fixed length IATA checking Select variable length IATA Disable c...

Page 20: ...25 Min Length SS MS Default 06 01 Maximum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate this selection automatically FIN 2 digits Code 25 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate this selection automatically FIN 2 digits German Postal Setting SS SS Disable Enable 0 1 The DelfiScan ...

Page 21: ... terminate this selection automatically FIN 2 digits Code 11 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate this selection automatically FIN 2 digits Code 93 Setting SS SS Disable check digit transmission Enable check digit transmission 0 1 Code 93 Min Lenght SS MS Default 03 01 Maximum Scan 2 digits from the option code ch...

Page 22: ...ction automatically FIN 2 digits MSI Plessey Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate this selection automatically FIN 2 digits Code 128 EAN 128 Setting SS SS SS SS Disable check digit transmission Enable check digit transmission ISBT Concatenation On ISBT Concatenation Off 0 1 2 3 Code 128 EAN 128 Min Length SS MS De...

Page 23: ...n automatically FIN 2 digits UK Plessey Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then DelfiScan will terminate this selection automatically FIN 2 digits Telepen Setting SS SS SS SS Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission 0 1 2 3 Telepen Min Length SS MS Default 04 ...

Page 24: ...on Option Code GS1 DataBar RSS 14 Setting SS SS SS SS SS SS Disable GS1 DataBar RSS 14 decoder Enable GS1 DataBar RSS 14 decoder Disable limited GS1 DataBar RSS 14 decoder Enable limited GS1 DataBar RSS 14 decoder Disable expanded GS1 DataBar RSS 14 decoder Enable expanded GS1 DataBar RSS 14 decoder 0 1 2 3 4 5 ...

Page 25: ... is only for PC AT PS VP PS 2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on off Output Style concern All transmitted data will follow the original full ASCII form You also need not worry about the upper lower case control Please refer to the ASCII HEX Table listed in the Appendix to determine HEX codes for characters symbols and functions to...

Page 26: ...ate Auto Detect PC AT PS 2 Keyboard Replacement and DOS V Machines only 0 1 2 Caps Lock Release Control SS SS Caps Lock On Caps Off Caps Lock On Shift Off 0 1 The function of Caps Lock Control and Key Pad Emulation are only available for IBM PC AT PS VP PS 2 series personal computers and compatible machines While selecting the other host interfaces these selections don t perform the above function...

Page 27: ...ix then C70 will terminate this selection automatically FIN 2 digits Character Frame Control is used to adjust timing gap between bytes within one character data output by C70 Intermessage Delay is a time delay between messages output by C70 Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a time delay between data characters output by C70...

Page 28: ...ut Ctrl Output Refer to Appendix Keyboard Function Code Table for details 0 1 Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad Num Lock On output 0 1 Upper Lower Case SS SS SS SS Normal case neglect the upper lower case control Inverse case change all characters output to inverse case Upper case force all characters output as upper case Lower case force all charac...

Page 29: ...DH LF 0AH CRLF 0D0AH TAB 09H SPACE 20H User defined character 1 character 0 1 2 3 4 5 6 00 7F Preamble SS MS None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7f FIN Postamble SS MS None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7f FIN Serial Interface Message String RS232 USB COM STX Preamble Data Length Prefix...

Page 30: ...minate this selection automatically FIN 2 digits Intermessage Delay is a time delay between messages output by C70 Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a time delay between data characters output by C70 These two parameters are used to synchronize data communication when 1 the data transmission speed is too fast characters may ...

Page 31: ... 2 0 1 2 3 4 5 6 7 8 9 A B C D E Time Out Control SS SS SS MS None 200 mseconds 500 mseconds 1 second 2 seconds 5 seconds User defined value seconds 0 1 2 3 4 5 6 2 digits When the RTS CTS Hardware Handshaking option is selected the RTS request to send and CTS clear to send signals will be issued before normal data communication This option is very helpful to ensure the reliability of data communi...

Page 32: ...ore data transmission 0 1 2 3 4 5 6 Module Time SS SS SS Extremely short Short Medium Long Time base of minimum narrow bar 0 1 2 3 Narrow Wide Ratio SS SS SS 1 2 1 2 5 1 3 0 1 2 Code 39 Emulation SS SS SS Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation 0 1 2 Code 39 Skip When this option is selected all scanned data will be transl...

Page 33: ...he scanner keeps the light source of the scanner turned on and disables the infrared sensor till the pre defined auto power off duration is up After the scanner turns off the light source you must press the trigger to turn on the light source again After each good read the auto power off timer counter is reset You do not have to press the trigger frequently it is very convenient for multiple scann...

Page 34: ...mely high Good read beep before data transmission Good read beep after data transmission Power on beep No power on beep 0 1 2 3 4 5 6 7 8 Power On Indicator SS SS Disable Power on LED off Enable Power on LED on as normal Unavailable for FBC6000 series 0 1 Vibrator SS SS Disable Enable Unavailable for FBC6000 series 0 1 Inverse Reading SS SS Disable Enable 0 1 Dollar Sign Control SS SS SS Dollar si...

Page 35: ...t Medium time out Long time out Force verification 0 1 2 3 4 5 Good Read Delay SS SS SS SS SS SS SS None 200 msec 500 msec 1 sec 1 5 sec 2 sec 3 sec 0 1 2 3 4 5 6 The Pulse Driven Duty is designed to control the flashing frequency of the light source The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted The Reread Delay is designed to inhibit Delf...

Page 36: ... time out counter for Automatic Mode You can adjust this parameter to meet your own application requirement The Force Mode and Presentation Modes are referred to as hands free modes If the imager s trigger is pulled when using a hands free mode the imager changes to manual trigger mode You can set the time for imager to remain in manual trigger mode by setting the Hands Free Time Out Once the time...

Page 37: ...g expert system provided specially for the DelfiScan family bar code readers Through DataWizard you can process the scanned data prior the transmissions in many ways as Insert Delete Match Verify Replace Reorganize and Repeat Transmission It will help you to arrange the transmission of scanned data to any specific format without software modification Due to the resources used by this system Full f...

Page 38: ...able Enable 2 digits identified position max 3 insertion characters FIN 2 digits position 1 3 characters FIN The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for formatter control and provides Multiple Position Insertion and Multiple Character Insertion max three characters...

Page 39: ...2 digits checking position 1 identified character FIN 2 digits position 00 7F The Data Verifier is used to provide advanced verification for error free scanning and to work as an Embedded Data Transmitting Filter All data must conform to the Identified Bar Code Symbologies Identified Data Length and one to three Identified Characters in the checking position Otherwise the DelfiScan will not transm...

Page 40: ...acter FIN 2 digits position 00 7F The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for replacer control and provides Multiple Position Replcement in the identified position All data must conform to the Identified Bar Code Symbologies and one to three Identified Characters in...

Page 41: ... identified position Transmitted data included the data of identified position 0 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for organizer control and provides maximum two identified positions to send the data forward or backward It also allows you to control the tra...

Page 42: ...X X X X X 00 01 02 03 04 05 Data Verifier Data Replacer Data Organizer If there is a 11 character data string please refer to the following to calculate the actual position for identification X X X X X X X X X X X 00 01 02 03 04 05 06 07 08 09 10 Application Example If your bar code label is a 16 digit Interleaved 2 of 5 which includes the information of 6 digit date code 6 digit serial number and...

Page 43: ...rtion and set the identified position to 16 then inserted character to 09 In the final you must scan FIN Finish code to terminate this selection Data Replacer Scan Replacer Control and set bar code symbology to 08 Scan 1st Replacement and set the identified position to 00 then replaced character to 41 Hex Code of A Data Organizer Scan Organizer Control and set bar code symbology to 08 Scan 1st Org...

Page 44: ... PAGE UP Edit 11 VT 0BH F3 27 ESC 1BH PAGE DOWN Edit 12 FF 0CH F4 28 FS 1CH UP Edit 13 CR 0DH ENTER CR 29 GS 1DH DOWN Edit 14 SO 0EH F5 30 RS 1EH LEFT Edit 15 SI 0FH F6 31 US 1FH RIGHT Edit High Byte of HEX Value Low Byte of HEX Value To emulate the keyboard function key input for user definable parameters user must configure actual content using the Reserved ASCII 0 31 characters and also Enable ...

Page 45: ...he Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the fold out back cover Scan the option code 4 listed on the fold out back cover Scan the system command FIN Finish to terminate Preamble setting Scan the system command End to exit the programming mode for normal operation HEX ASCII Reference Table H L 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 P p 1 SOH DC1 1 A Q a q...

Page 46: ... V Keyboard Wedge RS232 Serial Interface USB HID Interface Keyboard Replacement USB COM Interface Operation Mode Quick Set Lower Power Mode Force Mode Alternative Mode Trigger Mode Toggle Mode Flash Mode Presentation Mode Diagnostic Mode ...

Page 47: ...47 Option Codes 0 8 4 C 1 9 5 D 2 A 6 E 3 B 7 F ...

Page 48: ...48 System Commands PROGRAM Enter Programming Mode System Information List SYSLIST Save User Default FIN Finish Factory Default M_DEFAULT User Default END Exit Programming Mode PowerTool Host Link ...