Delco PN 09041C Operator'S Manual Download Page 10

Page 10

Versa 100/100C Owner's Manual

5.

If the oil is below the notch, add SAE 30 weight, non-detergent oil.

6.

Put the dipstick back into the hole.

7.

Turn the plug clockwise until it stops.

NOTE:  

Change the oil after the first 50 hours of use and then after every 500 hours of use.  SAE 30

weight oil must be used.

Freeze-Up Prevention

To prevent freeze-up follow these instructions:

1.

Drain the float tank.

2.

Remove the spray nozzle from the wand.

3.

Mix antifreeze concentrate and water in a large container.  Read the recommended mixing
instructions given with the antifreeze.

4

Fill the float tank with the antifreeze mixture.

5.

Put the end of the chemical line in the float tank.  Fully open the metering valve.

6.

Turn the control switch to position one.

7.

Let the pump run until the antifreeze moves through the pump, coils, and pressure hose.

NOTE

:

The trigger on the gun must be pulled to allow antifreeze to pass through the coils, and then the
trigger must be released to allow the antifreeze to pass through the bypass line.

8

Turn the control switch to the “O” position and close the metering valve.

9.

Unplug the cord and put the machine in a dry building.

How to Check/Clean the Heat Exchange Coil

The heat exchange coil should be inspected for deposit build-up after 40 hours of use, or once a month,
whichever comes first.  In hard water areas a water softening system should be employed.

Scaling or liming of the coils is caused by mineral deposits from the water and occurs much faster in hard-
water areas and with heavier machine usage.  Lime build-up can also be caused by inferior cleaning com-
pounds.

DANGER:

Failure to properly maintain the heat exchange coil can result in a steam explosion!
Scale or lime build-up will act as an insulation and decrease the efficiency of the
heat exchanger coil and will also cause "hot spots".  This can result in a weakening
of the tubing which can lead to a steam explosion.

Explicit instructions for inspecting and cleaning the heat exchange coil can be found in your Delco Operator
Safety Manual that came with your pressure washer.  The part number for that manual is 78351A.  If you
didn't receive one when you bought your pressure washer contact your local Delco distributor and request
one or call Delco's customer service department at 1-800-BUY-DELCO.

MAINTENANCE - Cont'd.

Summary of Contents for PN 09041C

Page 1: ...VERSA 100 VERSA 100C PN 09043X PN 09043D Operators Manual and Replacement Parts Book Pressu re Wash ers Delco Pressure Washers LIT VER1 DEL VERSA 200C PN 09041E PN 09041C S S Rev1 11 07...

Page 2: ...atisfy claims of the appropriate warranty provisions Normal wear items include but are not limited to Valves and Seals which are not covered by this warranty This Warranty replaces all other warrantie...

Page 3: ...ected by moving parts Electric Motors if applicable One 1 year from date of first start up Burners hot water machines One 1 year from date of first start up Hot Water Burner Coil hot water machines Fi...

Page 4: ...the Machine 11 12 Wiring Diagram 115V 13 Electrode Check Schematic 13 Pump Drawing 14 Parts List 15 Packings 16 KitInterchange CrossReference 17 Unloader Valve Drawing and Parts List 18 59420A Unloade...

Page 5: ...lifi WARNING If you smell gas shut off the gas supply to the appliance extinguish any open flame and test all joints with a soap solution If the odor persists call your gas supplier immediately ADVERT...

Page 6: ...the fuse circuit breaker or power supply and or contact your local authorized Delco distributor for assistance DANGER Electrocution could occur if maintenance and repairs are performed on a unit that...

Page 7: ...wer cord with a ground fault circuit interrupter GFCI for operator safety Features of the Versa 100 and 200 series are hose wraps hardened stainless steel nozzles with quick disconnects and a heavy du...

Page 8: ...position before resetting the GFCI 13 Point the wand towards the floor 14 Turn the control switch to position one I cold water wash While pointing the wand toward the floor squeeze the trigger on the...

Page 9: ...to the system which could cause a steam explosion Air introduced into the system will cause pump damage and create steam space if the burner is on The detergent level should never fall below the chemi...

Page 10: ...position and close the metering valve 9 Unplug the cord and put the machine in a dry building How to Check Clean the Heat Exchange Coil The heat exchange coil should be inspected for deposit build up...

Page 11: ...nning but the pressure The pump is sucking air Make sure the water supply is correct is low on installation metering valve closed or solution above above feed line The pump valves are sticking Contact...

Page 12: ...k is empty Fill the fuel tank with either 1 or 2 diesel or kerosene The fuel filter is dirty Change the fuel filter The burner motor does not run Push the reset button on the burner motor If the burne...

Page 13: ...Versa 100 100C Owner s Manual Page 13 Delco Versa 100 200 Versa 100C 200C Wiring Diagram Delco Versa 100 200 and Versa 100C 200C Electrode Check Schematic...

Page 14: ...Page 14 Versa 100 100C Owner s Manual Delco Versa 100 Versa 100C 200C Pump Drawing...

Page 15: ...1 Ref 38 Valve Assembly 6 195404Hex Valve Cover O Ring Kit 1 Ref 37 O Ring 6 Ref 36 Hex Valve Cover 6 195406Plunger Bolt Kit 1 Ref 27 Plunger Bolt 3 Ref 12 O Ring 3 Ref 24 Backup ring 3 Ref 23 Washer...

Page 16: ...Page 16 Versa 100 100C Owner s Manual...

Page 17: ...Versa 100 100C Owner s Manual Page 17...

Page 18: ...57A O ring in kit 59 13 Only a kit item see below 14 Only a kit item see below 15 56610A O ring 20 35 x 1 78 w kits 59 61 16 Only a kit item see below 17 Only a kit item see below 18 Only a kit item s...

Page 19: ...ring in kit 59 13 Only a kit item see below 14 Only a kit item see below 15 56610A O ring 20 35 x 1 78 w kits 59 61 16 Only a kit item see below 17 Only a kit item see below 18 Only a kit item see be...

Page 20: ...Page 20 Versa 100 100C Owner s Manual Delco Versa 100 100C Painted Models Machine Assembly Drawing...

Page 21: ...16 77033A Label Warning 1 x x 117 197056 Nipple Coupler Quick 3 8 Male 1 x x 118 170858 Washer Flat 1 4 SS 4 x x Part list continued on next page Ref P N Description Qty 1 29645A Pyrolite Drum Head In...

Page 22: ...ee 1 2 x 1 2 x 3 8 1 x x 134 56329A Nipple 1 4 x 21 2 Sch 40 1 x x 135 170221 Nipple Pipe 1 2 x 4 Galv 1 x x 136 198433 Switch Vacuum 1 x x 137 80501A Key 3 16 x 3 16 x 1 1 x x 138 170014 Plug Pipe 1...

Page 23: ...5A Gun Assembly 1 A 50330A Nozzle Adapter 1 B 53529A Electrode Assembly LH 1 C 53530A Electrode Assembly RH 1 D 51816A Electrode Clamp 1 E 54008A Oil Pipe Fitting 1 F 56427A Support Assembly 1 14 1936...

Page 24: ...Page 24 Versa 100 100C Owner s Manual Delco Versa 100C 200C Stainless Steel Machine Assembly Drawing...

Page 25: ...Shield Heat 18 S S 1 124 198078 Screen Hose Washer 1 125 170071 Fitting 3 4 x 1 2 Female 1 126 170216 Nipple Pipe 1 2 x Close Galv 1 127 170222 Nipple x 6 1 128 170402 Nipple Close Blk 1 Part list con...

Page 26: ...36 198433 Switch Vacuum 1 137 80501A Key 1 138 170014 Plug Pipe 1 2 Brass 1 140 170850 Nut Panel 5 16 18 6 141 170004 Bushing Pipe 3 8 x 1 8 Brass 1 142 199027 Valve Air 1 8 NPT Brass 1 143 57239A Pul...

Page 27: ...Versa 100 100C Owner s Manual Page 27 Delco Versa 100 100C 200C Fuel Filter Components Optional filter shown...

Page 28: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...