1.
Open the control box cover (A) and the
main cover (B).
2.
Disconnect all hoses (B) from the milk con-
tainer (A), then remove the container.
3.
Use a syringe without a needle to clean the
disconnected hoses.
3.1
Fill the syringe with lukewarm water,
press the tip of the syringe into one of
the hoses and then inject the water
through the hose. Repeat the same
procedure for all hoses.
3.2
If there are any dirt or milk residues left
in the hoses, remove the hoses and
rinse them with lukewarm water, then
wash them using a mild detergent,
then rinse again with water to remove
detergent.
3.3
If the milk sampler has not been
cleaned for a long time, milk residues
may be impossible to remove, in which
case the tubes is to be replaced. For
more information, see
4.
First disassemble the container, then rinse
it with lukewarm water and clean with
appropriate detergents. Finally, rinse again
with water to remove detergent.
5.
Reconnect the hoses onto the container.
Note! It is important not to shorten the
hoses too much if they have been deterio-
rated.
1
B
A
210235
A Control box cover
B Main cover
A
B
B
2
B
210237
A Milk container
B Disconnect hoses
Milk sampler (VMS 2012)
Operators maintenance
© DeLaval 2012.
2012-01-10, Version 1
12 (18)