2.3 Stopping a sampling sequence
A sampling sequence is stopped manually from
the touch screen, after a system cleaning.
1.
Put the milking station into manual mode
and start a system cleaning. The runner
then goes to the 0 (zero) point.
2.
After the system cleaning, press the
Stop
Milk Sampling
button on the Milk sampler
window.
3.
With the runner still in the 0 (zero) point
position, disconnect the milk sampler from
the milking station.
Note! The sampler must be disconnected
before milking restarts to avoid milk resi-
dues in the sampler during storage or trans-
portation.
4.
Remove the sample tray (B) and flush the
sample compartment (C). To prevent water
from damaging the electrical parts, close
the control box cover (A). Make sure that
the runner is clean.
5.
Check the silicone tubes for damage.
A
B
C
D
210232
A Control box cover
B Sample tray
C Sample compartment
D Runner at zero point
Milk sampler (VMS 2012)
Operation
© DeLaval 2012.
2012-01-10, Version 1
10 (18)
86352801