CLEANING & SERVICING

Cleaning chrome

•  Do not use abrasive, chlorine or any other acid-based cleaning products. Clean with hot, 

soapy water and a clean cloth or sponge. Dry using a clean, dry cloth.

Frost protection

•  Drain the pipes and operate the mixer several times to drain any remaining water.

REMEMBER

•  

Our mixers/taps and valves must be installed by professional installers

 in accordance 

with current regulations and recommendations in your country, and the specifications of the 
fluid engineer.

•  

Sizing the pipes correctly 

will avoid problems of water hammer and loss of pressure/flow 

rate. (See the calculation table in the brochure or on line at www.delabie.com).

•  

Protect the installation

 with filters, water-hammer absorbers or pressure reducers to reduce 

the frequency of maintenance. (Recommended dynamic pressure: 1-5 bar, 2 bar for siphon-
action urinals) to facilitate maintenance.

•  

Install stopcocks

 close to the mixer to facilitate maintenance.

•  The pipework, stopcocks, valves and all sanitary ware must be checked regularly.

Summary of Contents for TEMPOSOFT

Page 1: ...MACDONALD INDUSTRIES LIMITED INSTALLATION INSTRUCTIONS www macdonaldindustries co nz 1 TEMPOSOFT TEMPOSOFT 2 SOFT TOUCH TIME FLOW MIXER TAP AND VALVE...

Page 2: ...2 www macdonaldindustries co nz...

Page 3: ...tighten the bolts fig C on the fixing flange Install the filter joints fig D supplied exactly as shown in the diagram They will protect the nonreturn valves from damage Ensure a waterproof seal betwe...

Page 4: ...wall Leave a drainage point to allow any residual water to drain away Fix the wall plate in place Tighten using the nut Activate the valve several times to stabilise the temperature THE INSTALLER MUS...

Page 5: ...e cartridge then align the marker on the cartridge with the desired notch on the flow rate regulator Notch 1 maximum flow rate Notch 6 minimum flow rate MAXIMUM TEMPERATURE LIMITER ON MIXERS FIG G The...

Page 6: ...28mm spanner Automatic shut off takes too long or there is continuous flow fig K Clean the inside of the delay case using a clean dry cloth and clean the calibrated groove with a non metallic sharp po...

Page 7: ...llers in accordance with current regulations and recommendations in your country and the specifications of the fluid engineer Sizing the pipes correctly will avoid problems of water hammer and loss of...

Page 8: ...348 2356 F 03 348 2376 www macdonaldindustries co nz 03 17 Auckland Head Office 20 Carr Rd Three Kings Auckland 1042 P 09 624 1115 F 09 624 1110 E sales macdonaldindustries co nz Wellington P 04 569 8...

Reviews: