MAINTENANCE

Foreign bodies in the pipework can cause the mechanism to malfunction. To remove the 
mechanism (

fig. I

):

• Remove the grub screw 

 using a 2.5mm Allen key.

• Remove the push-button  .
• Unscrew the cartridge   using a 28mm spanner.

Automatic shut-off takes too long or there is continuous flow (fig. K)

•  Clean the inside of the delay case   using a clean, dry cloth; and clean the calibrated groove 

 with a non-metallic, sharp point.

• Check that the lip seal   and seat   are in good condition.
• Remember to replace the spring  .

Dripping or a constant trickle (fig. K)

• Clean the seat   or replace if damaged.
• Remember to replace the spring  .

Beware

: do not grease the inside of the mechanism.

Summary of Contents for TEMPOSOFT

Page 1: ...MACDONALD INDUSTRIES LIMITED INSTALLATION INSTRUCTIONS www macdonaldindustries co nz 1 TEMPOSOFT TEMPOSOFT 2 SOFT TOUCH TIME FLOW MIXER TAP AND VALVE...

Page 2: ...2 www macdonaldindustries co nz...

Page 3: ...tighten the bolts fig C on the fixing flange Install the filter joints fig D supplied exactly as shown in the diagram They will protect the nonreturn valves from damage Ensure a waterproof seal betwe...

Page 4: ...wall Leave a drainage point to allow any residual water to drain away Fix the wall plate in place Tighten using the nut Activate the valve several times to stabilise the temperature THE INSTALLER MUS...

Page 5: ...e cartridge then align the marker on the cartridge with the desired notch on the flow rate regulator Notch 1 maximum flow rate Notch 6 minimum flow rate MAXIMUM TEMPERATURE LIMITER ON MIXERS FIG G The...

Page 6: ...28mm spanner Automatic shut off takes too long or there is continuous flow fig K Clean the inside of the delay case using a clean dry cloth and clean the calibrated groove with a non metallic sharp po...

Page 7: ...llers in accordance with current regulations and recommendations in your country and the specifications of the fluid engineer Sizing the pipes correctly will avoid problems of water hammer and loss of...

Page 8: ...348 2356 F 03 348 2376 www macdonaldindustries co nz 03 17 Auckland Head Office 20 Carr Rd Three Kings Auckland 1042 P 09 624 1115 F 09 624 1110 E sales macdonaldindustries co nz Wellington P 04 569 8...

Reviews: