OPERATION – TIME FLOW VERSIONS
• References 763BOX-763000 and 763BOX-763040: press the anti-blocking push-button to operate.
Automatic timed shut-off.
OPERATION – DUAL CONTROL VERSIONS
(
Fig. W
page 18)
• 464SBOX-464000 and 464PBOX-464006: 2 operating modes.
-
voluntary activation by pressing the anti-blocking push-button and automatic timed shut-off.
The push-button operates autonomously: the flush operates even if the electricity supply fails.
-
or automatic activation when the user leaves.
Infrared electronic detection: detection delay is 10 seconds.
• 10 seconds rinse time (can be adjusted from 5 - 15 seconds depending on flush volume required or type of WC
pan (
image
).
• "Intelligent" automatic rinsing (
image
) :
- Use time less than 2 minutes: low flush volume
- Use time greater than 2 minutes: large flush volume
The timing can be adjusted from 1 to 3 minutes.
• In the event of the product being reset (30 seconds without supply), it restarts and carries out an opening
and closing cycle on the solenoid valve. The red LED is only visible flashing on the front during the first 10 user
detections.
• To avoid interference from infrared beams do not install the electronic mixer or tap opposite a mirror or bright object.
• Do not install two electronic mixers or taps opposite each other.
• Hygienic duty flush every 24 hours after the last use (can be adjusted to 12 hours or OFF) (
image
).
INSTALLATION
• For the UK market, the flush valve must be supplied by a centralised tank and a pump that ensures a dynamic
pressure of 1.2 bar minimum.
• Pressure: 1 bar (100kPa) to 5 bar (500kPa), we recommend 3 bar (300kPa).
• Required operating flow rate: 1 l/sec.
• The electrical installation must conform to local Electrical Regulations/Standards.
THE INTEGRITY OF THE SEALS BETWEEN THE WALL PLATE AND THE WALL MUST BE CHECKED AT LEAST
ONCE A YEAR, AND MORE FREQUENTLY IF NECESSARY, REPLACE THEM IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
ADJUSTING THE FLOW RATE
The flow rate can be adjusted from 2 to 9L:
• Time flow versions 763BOX-763000 and 763BOX-763040: turn the lever on the stopcock (
Fig. V1
page 12 or 15)
as well as the adjustment cog-wheel behind actuator plate (
Fig. V2
and
V3
page 12 or 15) until the required flush
volume is achieved.
• Dual control versions 464SBOX-464000 and 464PBOX-464006: turn the lever on the stopcock (
Fig. V1
page 18)
as well as the adjustment cog-wheels behind actuator plate (
Fig. V2
page 18) and/or the length of the rinse (
Fig. W,
image
page 18) until the required flush volume is achieved.
EN
Summary of Contents for TEMPOFLUX 3 763BOX-763000
Page 2: ...93 190 max 225 128 134 1 Kit 1 763BOX 464SBOX 464PBOX 1 P 3 60 min 60 min...
Page 3: ...P 11 P 14 P 16 2 186 186 210 162 170 170 Kit 2 763000 Kit 2 763040 Kit 2 464000 464006 2 2 2...
Page 4: ...Kit 1 763BOX 464SBOX 464PBOX B A 250 200 B1 B2 B1 B2 B3 B4 1 3...
Page 5: ...4 25 B4 25 25 180 25 25 70 24 B3...
Page 6: ...C1 C2 E D1 D2 32 5 F 100 240V 50 60 Hz 464SBOX 400 min...
Page 7: ...3 mm maxi G1 G2 6...
Page 8: ...I1 H2 H1 7...
Page 9: ...J K L CLIC CLIC CLIC M I2 8...
Page 10: ...O P 2 1 CLIC 45 N 9...
Page 11: ...Q Q1 Q2 10 763BOX R 464SBOX 464PBOX 464SBOX 464PBOX 763BOX...
Page 12: ...U Maxi 100 S T 11 Kit 2 763000 2...
Page 13: ...V3 V1 V2 CLIC CLIC CLIC CLIC CLIC CLIC 2 4L 4 9L 12...
Page 14: ...Y Z2 Z1 13 W X...
Page 15: ...Maxi 100 U T S 14 Kit 2 763040 2...
Page 16: ...X W V3 V2 CLIC CLIC CLIC CLIC CLIC CLIC 2 4L 4 9L 15 V1...
Page 17: ...100 Maxi S Y Z2 Z1 Kit 2 464000 464006 2 16...
Page 18: ...17 U2 U1 U T...
Page 19: ...V2 V1 CLIC CLIC CLIC 24H 12H 0H 5s 10s 15s 1min 2min 3min 24H 12h 0H 2min 2min 15 70 cm 18 W...
Page 20: ...19 Y X1 X2...
Page 21: ...Z1 Z2 2min 2min 100 50 20...
Page 22: ...AA AB AC AD AE 763MOD AF 763000 21...
Page 23: ...AF AD AB AA 763MOD AE AC 763040 22...
Page 24: ...AF AD AB AA 461032 AE AC 763MOD 464000 464006 23...