MAINTENANCE
The shower does not close or the operation time is incorrect:
• Impurities or damage to the O-ring inside the push-button starter
1
:
SPORTING shower panel
(fig. G)
:
- Unscrew the screws
4
and remove the end-cap
2
.
- Shut-off the water supply and remove the push-button starter. Unscrew the push-button starter
connection screw
20
for 3 turns, remove the covering cap of the push-button starter and apply
pressure with a screwdriver to remove the starter.
- Check/clean the O-rings
21
and
22
.
- Replace the push-button starter and covering cap and restore the water supply: press firmly
on the push-button and replace the screw
20 (fig. G, H)
which is inserted in the neck of the
push-button starter. Do not tighten the screw all the way.
- Replace the end-cap
2
and the screws
4
and restore the water supply.
Wall-mounted exposed or recessed SPORTING shower
(fig. H)
:
- Shut-off the water supply and remove the push-button starter using an Allen key.
- Check/clean the O-rings
21
and
22
.
- Replace the push-button starter using an Allen key and restore the water supply.
• Impurities or damage to the O-ring inside the shower head mechanism:
- Shut-off the water supply and remove the mechanism
23 (fig. I)
using a pair of circlip pliers
(fig. I)
making sure that you remove the washer
24 (fig. J)
. Remove the piston
27
and the spring
26 (fig. J)
.
- Clean the interior of the delay case
25 (fig. J, K)
with a cloth, then the thin calibrated groove
30
(fig. K)
with a non-metallic pointer, and check/clean the lip seal and O-ring washers
28
and
29 (fig. J)
.
- Replace the mechanism, remembering to include the washer
24 (fig. J)
and restore the water
supply.
The shower starts all by itself or the flow is very poor:
Impurities in the filter
8
and/or non-return valve
9
(figs.
A
,
B
,
C
,
E
): shut-off the water supply and clean them.
• Cleaning chrome: Do not use abrasive, chlorine or any other acid-based cleaning products. Clean
with soapy water using a cloth or sponge.
• Frost protection: Drain the pipes and operate the mixer several times to drain any remaining water.
• If the installation remains unused for a period of time we recommend removing the cartridge
mechanisms from the shower head and push-button starter and store them in the shade at room
temperature.
CLEANING & SERVICING
After Sales Care and Technical Support
:
For Douglas Delabie UK market only: Tel.
01491 824449
For all other markets: Tel.
03.22.60.22.74
The most recent version of this installation guide is available on: www.delabie.com
GB