background image

OPERATION

•  Press the push-button starter 

1

 (

Fig. A, B, G, H & J

) to open the valve.

•  Automatic shut-off after ~30 seconds (+5/-10 according to the European standard EN 816).

INSTALLATION

•  In order to capture all of the spray, install the shower tray 10cm from the wall: we recommend recessed 

shower trays or sloping gutters. If a small, raised shower tray is installed, the shower nozzle
can be replaced with a grid (Ref. GR) to concentrate the jet.

SPORTING shower panel with top inlet (Fig. A & C)

•  Position the panel so that the shower nozzle 

5

 is 2.10m from the floor.

•  Using the tool 

31

 (supplied) or a pair of circlip pliers unscrew the ring 

3

 and remove the cover 

7

.

•  Unscrew the 2 screws 

4

 using a Phillips screwdriver and remove the end-cap 

2

.

•  Mark and drill the 4 holes 

6

 and 

6’

.

•  Fix the panel in place using the 4 screws supplied (use rawl plugs that are suitable for the wall material).
•  Install the filter 

8

 (supplied) and connect to the mixed water supply (we recommend installing

a thermostatic mixing valve upstream).

•  Using a 3mm Allen key (not supplied), check that the stopcock 

32

 is wide open (anti-clockwise).

•  Supply with water and check for leaks.
•  Replace the cover 

7

 and tighten up the ring 

3

 using the tool 

31

 or a pair of circlip pliers.

•  Replace the end cap 

2

 and tighten the 2 screws 

4

.

SPORTING shower panel with back inlet (Fig. B, C, D, E & F)

•  Position the panel so that the shower nozzle 

5

 is 2.10m from the floor (or the water supply is 2.17m 

above the ground) (

Fig. B

).

•  Using the tool 

31

 (supplied) or a pair of circlip pliers, unscrew the ring 

3

 and remove the cover 

7

(

Fig. B & C

).

•  Remove the inlet assembly 

33

 by unscrewing nut 

34

 (

Fig. D

).

•  Do not lose the washer 

36

 (

Fig. D

).

•  Close the stopcock 

32

 (clockwise) using a 3mm Allen key (not supplied) (

Fig. E

).

•  Fully unscrew nut 

35

 (

Fig. E

).

•  Turn the threaded screw 

37

 and tighten nut 

35

 by hand (

Fig. E

).

•  Connect the mixed water supply (we recommend installing a thermostatic mixing valve upstream)

by screwing the threaded screw 

37

 into the wall fitting, making sure that the threaded part

has a waterproof seal. Tighten so that the groove 

38

 is in line with the mounting surface 

39

 (

Fig. F

).

•  Using a 3mm Allen key (not supplied), check that the stopcock 

32

 is closed (clockwise), open the water 

supply and check for leaks.

•  Use a Phillips screwdriver to unscrew the two screws 

4

 and the end cap 

2

 (

Fig. B

).

•  Position the panel, insert washer 

36

 and tighten nut 

34

 by hand (

Fig. D

).

•  Mark and drill the 4 holes 

6

 and 

6’

 (

Fig. B

).

•  Fix the panel in place using the 4 screws supplied (use rawl plugs that are suitable for the wall material).
•  Open the stopcock 

32

 (anti-clockwise) using a 3mm Allen key (not supplied) (

Fig. E

).

•  Slide the cap 

40

 into the slot on the cover 

7

 (

Fig. B

).

•  Replace the cover 

7

 and tighten the ring 

3

 using the tool 

31

 (

Fig. B & C

).

•  Replace the end-cap 

2

, tighten the 2 screws 

4

 (

Fig. B

).

EN

Exposed, wall-mounted SPORTING shower (Fig. G)

•  Position the shower diffuser

5

 2.10m from the floor. If necessary, insert the white plastic wedge

between the shower head and the wall to equalise the tile thickness.

•  Assemble the shower column 

10

 with the push-button starter

1

 and the collar

11

. Put the white

PVC tubes 

12

 into the column.

•  Insert the column into the hole beneath the shower diffuser

16

. Mark, drill then fix the column using

the 2 chrome-plated screws provided (use rawl plugs that are suitable for the wall type).

•  Position the collar

11

 in the middle of the column to cover the joint. Mark, drill then fix the collar

11

and the push-button starter

1

 using the 4 screws provided (use rawl plugs that are suitable for the type 

of wall).

•  Install the filter

8

 supplied to protect the non-return valve 

9

 and connect to the mixed water supply

(recommended max. 41°C for the UK and Ireland). Ensure that all the connections are waterproof.

Recessed, wall-mounted SPORTING shower (Fig. H & I)

•  Recess the connection pipe and connectors 

13-14

in the wall so that the shower diffuser

5

 is 2.10m

from the floor. Take care to maintain the recessing dimensions of the unions (0-9 mm from the exterior
wall surface) (

Fig. I

).

•  Remove the 2 plastic protective caps 

15

 (

Fig. I

).

•  Screw the shower head 

16

 on to the upper connection screw

17

which is situated inside the recessed 

upper union 

14

.

•  Screw the push-button starter

1

 on to the lower connection screw

18

which is situated inside

the recessed lower union 

14

.

•  Mark, drill then fix the shower head 

16

 and the push-button starter

1

 using the screws provided

(use rawl plugs that are suitable for the wall type).

•  Install the supplied filter

8

 to protect the non-return valve 

9

 and connect to the mixed water supply

(recommended max. 41°C for the UK and Ireland). Ensure that the all connections are waterproof.

Ceiling-mounted SPORTING shower (Fig. J)

•  Fix the shower head 

16

 to the water supply.

•  Mark, drill then fix the push-button starter

1

 1.10m from the floor shower using the screws provided 

(use rawl plugs that are suitable for the type of wall)

•  Connect the push-button starter

1

 and the shower head 

16

 with a tube 6/8 

19

 (not supplied).

•  To ensure it operates correctly, restrict the length of 6/8 connecting tube and the number of elbows

to a minimum (a maximum of 1 elbow).

•  Install the supplied filter

8

to protect the non-return valve 9 and connect to the mixed water supply

(recommended max. 41°C for the UK and Ireland). Ensure that the all connections are waterproof.

THE INSTALLER MUST ENSURE:
•  THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS OF

WATER;

•  ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN 

OFF, LEAKS, ETC.) HAS A DRAINAGE POINT TO PREVENT ANY STAGNATION;

•  THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL

OR THE WALL PLATE AND THE TAP AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.

If this advice is not followed, water may leak into the wall. DELABIE cannot be held 

responsible for any ingress.

FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821. 
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.

Summary of Contents for Delabie Sporting 714700

Page 1: ...ie of ingebruikname van de kraan over te gaan Перед установкой и подключением устройства тщательно промыть канализационные трубы напором воды Panneaux et ensembles de douche à fermeture automatique temporisée Shower panels and shower kits with automatic time flow shut off Duschelemente und Duschkombinationen mit automatischer Abschaltung Panele i zestawy natryskowe z automatycznym zamknięciem czas...

Page 2: ...A G H I B C F D 2220 2100 2170 2100 E 2170 2220 2170 2100 2220 2170 2100 0 9 mm 180 ...

Page 3: ...K L M N O P Q J 2220 2100 ...

Page 4: ...e panel so that the shower nozzle 5 is 2 10m from the floor or the water supply is 2 17m above the ground Fig B Using the tool 31 supplied or a pair of circlip pliers unscrew the ring 3 and remove the cover 7 Fig B C Remove the inlet assembly 33 by unscrewing nut 34 Fig D Do not lose the washer 36 Fig D Close the stopcock 32 clockwise using a 3mm Allen key not supplied Fig E Fully unscrew nut 35 F...

Page 5: ...uated inside the recessed lower union 14 Mark drill then fix the shower head 16 and the push button starter 1 using the screws provided use rawl plugs that are suitable for the wall type Install the supplied filter 8 to protect the non return valve 9 and connect to the mixed water supply recommended max 41 C for the UK and Ireland Ensure that the all connections are waterproof Ceiling mounted SPOR...

Page 6: ...efully tighten the nut 41 Replace the nozzle 5 taking care not to block it The flow rate can be adjusted Fig A B C Unscrew the ring 3 using the tool 31 supplied and remove the cover 7 Turn the stopcock 32 using a 3mm Allen key Once the flow rate has been adjusted replace the cover 7 and the ring 3 using the tool 31 supplied MAINTENANCE Fig A C K L P Q Exposed wall mounted recessed or ceiling mount...

Page 7: ...ore the water supply by opening the stopcock 32 anti clockwise Fig A or B Replace the cover 7 and tighten the ring 3 using the tool 31 or a pair of circlip pliers Fig A or B Frost protection Fig A B C D Shut off the mains water supply or the stopcock near the installed SPORTING shower Press the starter 1 on the SPORTING shower panel to reduce the pressure Remove SPORTING panel Using the tool 31 un...